27
For model MSC-12HRFN1-QD2E
9.7.8
Heating capacity test function.
1)
Set the indoor unit with remote controller as: high fan, 30
℃
in heating mode, then press
“
TURBO
”
button
on controller 6 times or more within 10 seconds(make sure indoor unit receives these signals), the machine will turn
into heating capacity test mode according to different ambient temperatures, the buzzer will make a
“
di
”
sound for 2
seconds continuously. Also, indoor fan speed and compressor frequency will be fixed as different values. Any condition
of above is not satisfied, the machine cannot be turned into heating capacity test mode.
on
off
on
off
on
off
on
off
compressor
4-way valve
outdoor fan
indoor fan
indoor fan breeze 10s
120s
130s
no longer than 10 minutes
30s
F8
Содержание MSC-09HRFN1-QD2E
Страница 10: ...7 3 2 Outdoor Unit MOC1 09HFN1 QD2E MOF 12HFN1 QD2E...
Страница 12: ...9 5 Refrigerant cycle diagram...
Страница 13: ...10 6 Wiring diagram 6 1 Indoor Unit MSC 09HRFN1 QD2E MSC 12HRFN1 QD2E...
Страница 14: ...11 6 2 Outdoor Unit MOC1 09HFN1 QD2E MOF 12HFN1 QD2E...
Страница 36: ...33...