![Midea MRO1744N Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/midea/mro1744n/mro1744n_manual_1791847005.webp)
3
The best working pressure for this device
ranges from 0.25 - 0.6Mpa. A corresponding
pressure increasing or decreasing device
should be installed if the water pressure is
higher or lower than this level
Avoid storing the unit in direct sunlight as it
may cause components to age. Avoid storing
or exposing the unit in an environment lower
than 0
The device must be installed or relocated by
a professional technician. If the product is
installed or dismantled incorrectly, it may
easily damage the components of the device
or cause risk of electric shock
When the inlet water does not meet the
municipal tap water standard (includes high
content of sand, mud, chlorine), please install
a pretreatment device in front of this product
If the device becomes faulty, quickly cut off
the water supply and contact a local service
technician
When the environment temperature is low,
the flow rate will drop which is a natural
property of the RO film