16.4 KJR-25B
16.4.1 Operation of buttons
Returns display to current
time and temperature.
Measures and displays
heating and cooling system
operating time for Today,
Yesterday,This Week,Last
Week,or Total.
For entering Time
EMER Mode
EMER
TIME
TEM P
FAN
SYSTEM
OFF
COOL
HEAT
ON
AUTO
Front Door:
Cover keys Open with one finger from left or right.
Heat,Cool,and Off.
Selector switch for
System Switch:
operation.
or Continuous fan
switch for Automatic
Fan Switch: Fan
functions.
Time,Program,and Span
and decreasing selections in the
setting. Also used for increasing
changing the Temperature
Up and Down Key:Key for
ENER
RUN
/return
Backlight key
Program Number,and other feature information
LCD Display:Shows Time,Day,Temperature,
as required.
Structure of thermostat and explanation for the keypads
T IM E
EN E R
E M E R
R U N
Measures and displays
heating and cooling system
operating time for Today,
Yesterday,This Week,Last
Week,or Total.By monitoring
your energy usage,you can
program the thermostat to
optimize energy savings.
For entering Time
Returns display to current
time and temperature.
EMER Mode
16.4.2 Features
Compressor protection
The thermostat provides a 4 minutes delay after shutting of the heating or cooling system before it can be
restarted. This feature will prevent damage to your compressor caused by rapid cycling. Note that this
delay also applies to the heating system control. It does not provide a delay when there are power
outages. You can select the function on or off at the configuration.
Temperature range
This thermostat can be programmed between 45
℉
and 95
℉
(7
℃
~35
℃
) However, it will display room
temperatures from 30
℉
to 99
℉
(0
℃
~37
℃
) “HI” will be displayed if the temperature is higher than 99
℉
(37
℃
). and “LO” will be displayed if the temperature is lower than 30
℉
(0
℃
). This thermostat will
automatically cutoff in Heat mode if the temperature rises above 95
℉
(35
℃
).And automatically cutoff in
Cool mode if the temperature drops below 45
℉
(7
℃
).
Power failure
Whenever the main power is interrupted or fails, the battery power retains and current time. This
thermostat has permanent memory, although you will have to reset your clock when there are power
outages.
Power supply
The thermostat shall be powered by 24 VAC and with batteries as backup.
Battery warning
Содержание MRC-36CWN1-V10
Страница 13: ...MCAC RTSM 2014 03 R410A Rooftop Package Unit 60Hz 13 7 Dimensional Drawing 3 5ton ...
Страница 14: ...R410A Rooftop Package Unit 60Hz MCAC RTSM 2014 03 14 8 Wiring Diagram 8 1 MRC 36CWN1 V10 ...
Страница 15: ...MCAC RTSM 2014 03 R410A Rooftop Package Unit 60Hz 15 8 2 MRC 48CWN1 V10 ...
Страница 16: ...R410A Rooftop Package Unit 60Hz MCAC RTSM 2014 03 16 8 3 MRC 60CWN1 V10 ...
Страница 17: ...MCAC RTSM 2014 03 R410A Rooftop Package Unit 60Hz 17 MRC 60CWN1 X10 ...
Страница 25: ...MCAC RTSM 2014 03 R410A Rooftop Package Unit 60Hz 25 10 Explode View 10 1 Explode view for 3 4 5 ton ...