background image

EasyCool Portable

version A - 03 - 2017

USER MANUAL

en

MPF

Warning notices: Before
using this product, please
read this manual carefully
and keep it for future
reference.
The design and
specifications are subject to
change without prior notice
for product improvement.
Consult with your dealer or
manufacturer for details.

Rated voltage: 115V
Rated power: 900 ~ 1575W
Frequency: 60Hz
Capacity: 8000 ~ 14000BTU/h

MPF08CR71

 

MPF10CR71

 

MPF12CR71

 

 

MPF14CR71

 

www.midea.com

Содержание MPF08CR71

Страница 1: ...efully and keep it for future reference The design and specifications are subject to change without prior notice for product improvement Consult with your dealer or manufacturer for details Rated volt...

Страница 2: ......

Страница 3: ...e technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intented for use by young children or infirm persons without supervis...

Страница 4: ...n the side of the unit behind the grille Install the unit in on a flat sturdy surface Failure to do so could result in damage or excessive noise and vibration The unit must be kept free from obstructi...

Страница 5: ...for their safety be applicable for other countries except the European Countries Children should be supervised to ensure that they do not play with the appliance If the supply cord is damaged it must...

Страница 6: ...air filter Lower air intake Drain outlet Design Notice In order to ensure the optimal performance of our products the design specifications of the unit and remote control are subject to change withou...

Страница 7: ...0 CFM 176 176 206 224 Indoor side noise level Hi dB A 55 55 56 56 Refrigerant type ozs R410A 9 17 R410A 10 58 R410A 13 76 R410A 20 46 Plug type NEMA 5 15P 5 15P 5 15P 5 15P Control type Remote Control...

Страница 8: ...eminder NOTE Press this button for 3 seconds to initiate ION feature The ion generator is energized and will help to remove pollen and impurities from the air and trap them in the filter Press it for...

Страница 9: ...temperature in C or F and the Auto timer settings While on DRY and FAN modes it shows the room temperature Shows Error codes and protection code E1 Room temperature sensor error E2 Evaporator temperat...

Страница 10: ...t be adjusted Do not put the duct to window TIMER operation When the unit is on press the Timer button will initiate the Auto off stop program the TIMER OFF indicator light illuminates Press the UP or...

Страница 11: ...Sensing button again If the unit does not receive the Follow Me Temp Sensing signal during any 7 minutes interval the unit will beep to indicate the Follow Me Temp Sensing mode has ended AUTO RESTART...

Страница 12: ...e drain connector 5 8 universal female mender with 3 4 hose locally purchased For the models without drain connector just attach the drain hose to the hole Place the open end of the Hose adaptor direc...

Страница 13: ...nit that contains fluorinated gasses For specific information on the type of gas and the amount please refer to the relevant label on the unit itself Installation service maintenance and repair of thi...

Страница 14: ...on Unit adaptor Window slider adaptor Window slider A Window slider B Exhaust hose Bolt Foam seal A adhesive Foam seal B adhesive Foam seal C Non adhesive Security bracket and 2 screws Drain hose Drai...

Страница 15: ...n the Exhaust hose assembly along the arrow direction for installation Step Three Preparing the adjustable window slider 1 Depending on the size of your window adjust the size of the window slider 2 I...

Страница 16: ...Foam seal A Adhesive type Window slider A Window slider B if required Foam seal C Non adhesive type Security Bracket 2 Screws Installation Instructions 2 Insert the window slider assembly into the wi...

Страница 17: ...C strip to match the window height Insert the foam seal between the glass and the window frame to prevent air and insects from getting into the room 4 If desired install the security bracket with 2 sc...

Страница 18: ...ly was damaged during cleaning A damaged power cord must be replaced with a new cord from the manufacturer Clean the unit using a damp lint free cloth and mild detergent Dry the unit with a dry lint f...

Страница 19: ...r is blocked Turn off the unit disconnect the hose check for blockage and reconnect the hose The unit is low on refrigerant Call a service technician to inspect the unit and top off refrigerant Temper...

Страница 20: ...urn unit off see How to Use Basic Functions for instructions LED Turns indoor unit s LED display on and off If you are sensitive to light when you go to sleep you can press the LED button to turn off...

Страница 21: ...r disposal of batteries TIPS FOR USING REMOTE CONTROL The remote control must be used within 8 meters 26 feet of the unit The unit will beep when remote signal is received Curtains other materials and...

Страница 22: ...for this unit SLEEP display Displays when SLEEP function is activated SILENT display Not available for this unit FAN SPEED display Displays selected FAN SPEED HIGH MED LOW This display is blank when s...

Страница 23: ...he unit will automatically select the COOL FAN HEAT or DRY mode based on the set temperature 1 Press the MODE button to select Auto mode 2 Set your desired temperature using the Temp or Temp button 3...

Страница 24: ...tion 1 Press the MODE button to select FAN mode 2 Press FAN button to select the fan speed AUTO LOW MED or HIGH 3 Press the ON OFF button to start the unit 1 2 3 ON OF F T E MP SHORT CUT TIMER ON TIME...

Страница 25: ...the amount of time after the current time that you want the unit to turn on For example if you set TIMER ON for 2 hours 2 0h will appear on the screen and the unit will turn on after 2 hours NOTE This...

Страница 26: ...DE SH OR T CU T TIME R ON TE MP sec 4 ON OFF MO DE SH OR T CU T TIME R ON TE MP sec 8 1 TIMER ON X12 2 TIMER ON 5 TIMER OFF X16 6 TIMER OFF 3 7 Setting both TIMER ON and TIMER OFF at the same time Ke...

Страница 27: ...imize the temperature around you and ensure maximum comfort 1 Press FOLLOW ME button to activate function The remote control will send temperature signal to the unit every three minutes 2 Press FOLLOW...

Страница 28: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio...

Страница 29: ...municipality has established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at...

Страница 30: ......

Страница 31: ......

Страница 32: ......