Midea ML2EC10SABS Скачать руководство пользователя страница 7

1) Remove the outer case.
2) Disconnect two terminals, and remove one screw of

the earth terminal.

MEASUREMENT OF MICROWAVE POWER OUTPUT

• 

Microwave power output measurement is made with

the microwave oven supplied at its rated voltage and
operated at its maximum microwave power setting with
a load of (1000±5) g of potable water.

• 

The water is contained in a cylindrical borosilicate glass

vessel having a maximum material thickness of 3 mm
and an outside diameter of approximately 190mm.

• 

The oven and the empty vessel are at ambient

temperature prior to the start of the test.

• 

The initial temperature (T1) of the water is (10±2)°C. It

is measured immediately before the water is added to
the vessel. After addition of the water to the vessel,
the load is immediately placed on the center of the
turntable which is in thd lowest position and the
microwave power switched on.

• 

The time T for the temperature of the water to rise by a

value ∆ T of (10±2)°K is measured, where T is the time
in seconds and ∆T is the temperature rise. The initial
and final water temperatures are selected so that the
maximum difference between the final water
temperature and the ambient temperature is 5°K.

4187 x (∆T) + 0.55 X (T

2

- T

0

) X M

T

• 

T

2

: Temperature after heating

• 

T

0

: Temperature of bowl

• 

M: Weight of bowl

is measured while the microwave generator is

operating at full power. Magnetron filament heat-up
time is not included. (about 3 sec)

• 

The water is stirred to equalize temperature throughout

the vessel, prior to measuring the final water
temperature.

• 

Stirring devices and measuring instruments are

selected in order to minimize addition or removal of
heat.

WATER LOAD

TURNTABLE

P =

• 

The microwave power output P in watts is calculated

from the following formula :

NOTES:

For simple tests of micromave power output,

 it by heating one litre water for one minute,

minimum temperature rise should be 6  C 

°

conduct

DISASSEMBLY AND ADJUSTMENT

CAUTION: DISCHARGE THE HIGH VOLTAGE 

CAPACITOR BEFORE SERVICING

(refer to page 1)

2. POWER SUPPLY CORD REMOVAL

5

1) Disconnect the power supply cord from the outlet.
2) Remove the screws from the rear and along side

edges of the case.

The outer case must be moved backward to be

1) Disconnect the leadwire from the PCB SUB ASS’Y.
2) Remove the screws for the earth and securing the

control panel.

3) Lift control panel ASS’Y from the oven by the tab

unhooked.

1. OUTER CASE REMOVAL

3. CONTROL PANEL ASSEMBLY

lifted off.

 

 REMOVAL

Содержание ML2EC10SABS

Страница 1: ...er sales service only The content are subject to change without prior notice In interest of user safety the appliance should be restored to its original condition and only parts identical to those sho...

Страница 2: ...y Cord Removal 1 Outer Case Removal 2 3 Control Panel Assembly Removal 4 Door Assembly Removal 5 High Voltage Transformer Removal 6 Ori ce Assembly Removal 7 H V And Diode Removal 8 Air Guide Assembly...

Страница 3: ...on be assembled to the waveguide and cavity Never operate the magnetron unless it is properly installed Be sure that the magnetron gasket is properly installed around the dome of the tube whenever ins...

Страница 4: ...rface at least 10 cm 4 inches from the wall 7 Place the microwave oven as far away as possible from TV RADIO COMPUTER etc to prevent interference EARTHING INSTRUCTIONS This microwave oven is designed...

Страница 5: ...hich is graduated to 600 cc and place the beaker on the center of the turntable Set the energy leakage monitor to 2450 MHz and use it following the manufacturer s recommended test procedure to assure...

Страница 6: ...e test probe must be removed no faster than 1 inch sec 2 5 cm sec along the shaded area otherwise a false reading may result The test probe must be held with the grip portion of the handle A false rea...

Страница 7: ...etween the nal water temperature and the ambient temperature is 5 K 4187 x T 0 55 X T2 T0 X M T T2 Temperature after heating T0 Temperature of bowl M Weight of bowl is measured while the microwave gen...

Страница 8: ...from magnetron high voltage transformer and capacitor 3 Remove the screw holding the high voltage transformer to the baseplate 1 Discharge the high voltage capacitor 2 Disconnect the leadwire from fan...

Страница 9: ...over s projecting part to the base plate slit Waveguide Magnetron Gasket Magnetron Dome Waveguide Bracket Magnetron guide lacing NOTE 1 Remove the wire lead from the turntable motor VERY CAREFULLY 2 B...

Страница 10: ...the oven assembly Adjust the latch board in the arrow direction so that oven door will not have any play in it when the door is closed Tighten the mounting screw Check for play in the door by pushing...

Страница 11: ...should indicate an closed circuit When the secondary switch operation is abnormal make the necessary adjustment or replace the switch only with the same type of switch MONITOR SWITCH TEST Disconnect...

Страница 12: ...E RESULTS HIGH VOLTAGE TRANSFORMER Wire leads removed MAGNETRON Wire leads removed 1 Measure the resistance Ohm meter scale Rx1 Primary winding Secondary winding Filament winding 2 Measure the resista...

Страница 13: ...le Rx1000 Terminal to case Measure the continuity Forward Ohm meter scale Rx10000 Measure the continuity Reverse Ohm meter scale Rx10000 Normal Momentarily indicates several ohms and then gradually re...

Страница 14: ...fuse at the same time Replace just the fuse if the switches operate normally Normal Abnormal HEATER ELEMENT Wire leads removed Measure the resistance Multi meter scale Rx1 Measure the resistance with...

Страница 15: ...TOR NOT THE WIRES 1 3 5 Measure the resistance Ohm meter scale R x 1 Normal Abnormal or several 00 500 1 Cooking Start OFF Normal Approx 100 200K Abnormal or several L V Transformer of P C B Refer to...

Страница 16: ...e plug outlet and using them at the same time causes overloading Microwave oven plug is not inserted tightly Output power is too low Low AC input voltage Food temperature is too low Using metallic war...

Страница 17: ...t ickering NOTE Slight ickering is normal 2 Colon does not turn on or blink 3 A distinct change in the brightness of one or more numbers in display 4 One or more digits in the display are not lighting...

Страница 18: ...itor Defective high volt age transformer Replace high volt age transformer Replace fuse TROUBLE 2 Oven does not operate at all Display window does not display any gures and no input is accepted NOTE A...

Страница 19: ...door closed Check fan motor Check oven lamp Abnormal Abnormal Normal Defective fan motor Defective oven lamp Replace fan motor Replace oven lamp Loose connection Connection then tightly 17 Output is l...

Страница 20: ...ace high voltage transformer Check H V transformer normal normal Abnormal Defective high voltage Diode Replace high voltage Diode Check H V diode Abnormal Defective high voltage capacitor Replace high...

Страница 21: ...ion the thermostat Replace Thermostat and relay4 Grill Normal 1 Lower tempera ture the oven Abnormal Malfunction the heater Replace Heater Normal Abnormal Malfunction the thermostat Replace Thermostat...

Страница 22: ...lay3 Convection No continuity Open or loosen Replace or connect tightly Wire connection NOTE Make sure the wore leads correct position When removing the wire leads from parts be sure to grasp the conn...

Страница 23: ...ATTACHED FILES LIST 1 Exploded View 2 Spare Parts List 3 Wiring Diagram Note The manual may update without prior notice Please download the latest version on website https tsp midea com 21...