Wiring routing must be properly arranged so that control 
board cover is fixed properly. 

If  control  board  cover  is  not  fixed  perfectly,  it  will  cause 
heat-up  at  connection  point  of  terminal,  fire  or  electrical 
shock.

If the supply cord is damaged, it must be replaced by the 
manufacture  or  its  service  agent  or  similarly  qualifued 
person in order to avoid a hazard.

An  all-pole  disconnection  swith  having  a  contact 
separation  of  at  least  3mm  in  all  poles  should  be 
connected in fixed wiring.

When carrying out piping connection, take care not to let 
air substances go into refrigeration cycle. 

Otherwise,  it  will  cause  lower  capacity,  abnormal  high 
pressure in the refrigeration cycle, explosion and injury.

Do not modify the length of the power supply cord or use 
of extension cord, and do not share the single outlet with 
other electrical appliances. 

Otherwise, it will cause fire or electrical shock.

Carry out the specified installation work after taking into 
account strong winds, typhoons or earthquakes.

Improper installation work may result in the equipment falling 
and causing accidents.

If  the  refrigerant  leaks  during  installation,  ventilate  the 
area immediately.

Toxic gas may be produced if the refrigerant comes into the 
place contacting with fire.

The temperature of refrigerant circuit will be high, please 
keep  the  interconnection  cable  away  from  the  copper 
tube.

After  completing  the  installation  work,  check  that  the 
refrigerant does not leak.

Toxic  gas  may  be  produced  if  the  refrigerant  leaks  into  the 
room and comes into contact with a source of fire, such as a 
fan heater, stove or cooker.

To install properly, please read this "installation manual" at 
first.

The air conditioner must be installed by qualified persons.

When installing the indoor unit or its tubing, please follow 
this manual as strictly as possible.

If  the  air  conditioner  is  installed  on  a  metal  part  of  the 
building,  it  must  be  electrically  insulated  according  to  the 
relevant standards to electrical appliances.

When  all  the  installation  work  is  finished,  please  turn  on 
the power only after a thorough check.

Regret for no further announcement if there is any change 
of this manual caused by product improvement.

2.    INSTALLATION INFORMATION

Ground the air conditioner.

Do  not  connect  the  ground  wire  to  gas  or  water  pipes, 
lightning  rod  or  a  telephone  ground  wire.Incomplete 
grounding may result in electric shocks.

Be sure to install an earth leakage breaker.

Failure  to  install  an  earth  leakage  breaker  may  result  in 
electric shocks.

Connect the outdoor unit wires , then connect the indoor 
unit wires.

 

You  are  not  allow  to  connect  the  air  conditioner  with  the 
power  source  until  wiring  and  piping  the  air  conditioner  is 
done.

While  following  the  instructions  in  this  installation 
manual,  install  drain  piping  in  order  to  ensure  proper 
drainage  and  insulate  piping  in  order  to  prevent 
condensation.

Improper  drain  piping  may  result  in  water  leakage  and 
property damage.

Install the indoor and outdoor units, power supply wiring 
and  connecting  wires  at  least  1  meter  away  from 
televisions  or  radios  in  order  to  prevent  image 
interference or noise.

Depending on the radio waves, a distance of 1 meter may not 
be sufficient enough to eliminate the noise.

The appliance is not intended for use by young children 
or infirm persons without supervision.

Don't install the air conditioner in the following locations:

There is petrolatum existing.

There is salty air surrounding (near the coast).

There is caustic gas (the sulfide, for example) existing 

in the air (near a hot spring).

The Volt vibrates violently (in the factories).

In buses or cabinets.

In kitchen where it is full of oil gas.

There is strong electromagnetic wave existing.

There are inflammable materials or gas.

There is acid or alkaline liquid evaporating.

Other special conditions.

INSTALLATION ORDER

Select the location;

Install the indoor unit;

Install the outdoor unit;

Install the connecting pipe ;

Connect the drain pipe;

Wiring;

Test operation.

CAUTION

Содержание MFA-12HRDN1-Q

Страница 1: ...ding Type OWNER S MANUAL REMOTE CONTROLLER INSTALLATION Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference ...

Страница 2: ...ote controller All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail NOTE Air flow louver at air outlet Air inlet with air filter in it INDOOR UNIT OUTDOOR UNIT 1 6 7 1 3 4 2 5 7 8 9 Water tray Fig 1 ...

Страница 3: ... service the equipment Improper installation repair and maintenance may result in electric shocks short circuit leaks fire or other damage to the equipment Install according to this installation instructions strictly If installation is defective it will cause water leakage electrical shock fire When installing the unit in a small room take measures against to keep refrigerant concentration from ex...

Страница 4: ... part of the building it must be electrically insulated according to the relevant standards to electrical appliances When all the installation work is finished please turn on the power only after a thorough check Regret for no further announcement if there is any change of this manual caused by product improvement 2 INSTALLATION INFORMATION Ground the air conditioner Do not connect the ground wire...

Страница 5: ...thers 4 Mounting screw ST2 9 10 C H Fig 3 1 Never throw or beat the controller Before installation operate the remote controller to determine its location in a reception range Keep the remote controller at least 1m apart from the nearest TV set or stereo equipment it is necessary to prevent image disturbances or noise interferences Do not install the remote controller in a place exposed to direct ...

Страница 6: ... prevent image interference and noise in those electrical appliances Noise may be generated depending on the conditions under which the electric wave is generated even if 1 meter is kept There is enough room for installation and maintenance Refer to Fig 5 1 and Fig 5 2 The outlet and the inlet are not impeded and the influence of external air is the least The air flow can reach throughout the room...

Страница 7: ... Refer to Fig 6 1 If possible do not install the unit where it is exposed to direct sunlight If necessary install a blind that does not interfere with the air flow During the heating mode the water drained off the outdoor unit The condensate should be well drained away by the drain hole to an appropriate place so as not to interfere other people Select the position where it will not be subject to ...

Страница 8: ...eful when lifting it with a sling Never hold the inlet of the outdoor unit to prevent it from deforming Do not touch the fan with hands or other objects Do not lean it more than 45 and do not lay it sidelong Make concrete foundation accoding to the sepecif ications of the outdoor units Refer to Fig 6 6 Fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthqua...

Страница 9: ...e any winding The total length of the drain pipe when pulled out traversely shall not exceed 20m when the pipe is over long a prop stand must be installed to prevent winding Refer to the figures on the right for the installation of the pipes 8 CONNECT THE DRAIN PIPE Install the drainpipe of the indoor unit The outlet has PTI screw bread Please use sealing materials and pipe sheath fitting when con...

Страница 10: ...gram located on the panel of the outdoor unit to connect the wire The connection cables of indoor and outdoor units have been connected to the terminals on the control board Remove the control cover from the outdoor unit by loosening the screw Hold the indoor plug connector and insert the mating plug connector located on the outdoor unit until it fixed with a clicking sound Secure the cable onto t...

Страница 11: ...order to avoid electric shock make sure that the unit is grounded and that the earth wire is not connected to gas or water pipe lightning conductor or telephone earth wire In order to avoid injury do not remove the fan guard of the outdoor unit Do not operate the air conditioner with a wet hand An electric shock may happen Do not touch the heat exchanger fins These fins are sharp and could result ...

Страница 12: ...ils AUTO The OPERATION lamp is lit and the air conditioner will run under AUTO mode The remote controller operation is enabled to operate according to the received signal FORCED COOL The air conditioner will turn to AUTO after it is enforced to cool with a wind speed of LOW for 30 minutes The remote controller operation is disabled COOLING TEST Partial units have this function The function just be...

Страница 13: ...low direction properly to avoid winding toward your body Adjust the room temperature properly to get a comfortable situation and to avoid supercooling and superheat In cooling close the curtains to avoid direct sunlight To keep cool or warm air in the room never open doors or windows more often than necessary Set the timer for the desired operating time Never put obstructions near the air outlet o...

Страница 14: ...the operating mode or situation air blows from the upper air outlet Use this switch when you do not want air coming out of the lower air outlet While sleeping stc Operating mode Situation Blowing pattern COOL mode HEAT mode When the room has become fully cool or when one hour has passed since turning on the air condition er So that air does not come into dir ect contact with people air is blo wn u...

Страница 15: ...uum cleaner Refer to Fig 7 4 The air in side should face down when using water Refer to Fig 7 5 Press the claws on the right and left of the air filter down slig htly then pull upward Refer to Fig 7 2 Take off the especial function filter 3 Hold the tabs of the frame and remove the claws in 4 places Refer to Fig 7 3 The especial function filter can be renewed by washing it with water once every 6 ...

Страница 16: ...inuous low shah sound is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the system stops after heating operation Expansion and contraction of plastic parts caused by temperature change make this noise Symptom 4 2 Indoor unit outdoor unit A continuous low hissing soun...

Страница 17: ...unlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrige rant Wait for the comeback of power Switch on the power ReplLocation Replace the batterises or check the con troller Set the temperature properly Wait Check leakage and rightly recharge ref rigerant Vacuum and recharge refrigerant Maintenance or change compressor Install manostat Find r...

Страница 18: ...e ON OFF button is pressed Check whether the signal transmitter of the remote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears ...

Страница 19: ... ON to 0 00 ECONOMIC RUNNING Button Press this button to go into the Energy Saving operation mode Press the button again to cancel TIMER OFF Button Press this button to preset the time OFF turn off the operation Each press will increase the time OFF setting in 30 minutes increments When the setting time displays 10 00 each press will increase the time OFF setting in 60 minutes increments To cancel...

Страница 20: ...seconds the signal h disappears and the set temperature will re appear on the digital display 1 2 3 The Remote Controller uses two alkaline dry batteries LR03X2 Use the MODE select button to select AUTO Push the TEMP button to set the desired room temperature The most comfortable temperature setting are between 21 ć to 28ć Push the ON OFF button to start the air conditioner The OPERATION lamp on t...

Страница 21: ...er and the receiver of indoor unit otherwise the air conditioner will not work Keep the Remote Controller away from any liquids Protect the remote controller from the high temperatures and exposure to radiation Keep the indoor receiver out of direct sunlight or the Air Conditioner may malfunction Keep Remote Controller away from EMI Electro Magnetic Interference supplied by other household applian...

Страница 22: ...QSZIU 001AEN 202000100543 ...

Отзывы: