Midea MDV-D18Q1/N1-D Скачать руководство пользователя страница 24

MCAC-VTSM-2014-06 

 

One-way Cassette Type 

24 

10. Accessories 
Standard accessories 

MDV-D18Q1/N1-D    MDV-D22Q1/N1-D

   

MDV-D28Q1/N1-D

     

MDV-D36Q1/N1-D

 

Name 

Quantity 

Outline 

Function 

Indoor unit   
installation manual 

This manual 

Please hand to the user 

Installation paper plate 

 

For installing the suspender and cutting the ceiling 

Protection sleeve for   
refrigerant inlet and outlet pipes 

 

For heat insulation of the pipe connections 

Fastening belt 

10 

 

For fastening 

Flexible drainage pipe 

 

For  the  connection  between  the  air-conditioner 
and the drainage pipe 

Clasp 

 

For fastening the flexible drainage pipe 

Big gasket 

 

Necessary fastener for hanging the air-conditioner 

Screw 

 

Necessary fastener for hanging the air-conditioner 

Panel installation bolt 

 

For installing the panel to the air-conditioner 

Operation manual for   
remote controller 

 

Please hand to the user 

Remote controller 

 

For remotely controlling the unit 

Remote controller support 

 

For placing the remote controller 

Battery 

 

Battery for remote controller 

Cross-recessed countersunk head 
self tapping screw 

 

For fixing the remote controller support 

Small flathead screwdriver 

 

Use for installing the wires and dial codes 

Copper 

 

Use for pipe connection of engineering installation 

   

MDV-D45Q1/N1-C    MDV-D56Q1/N1-C 

Name 

Quantity 

Shape 

Usage 

Installation manual 

Pipe insulation material 

 

Heat insulation 

Remote controller 

 

7# alkaline battery 

 

Installation pattern paper 

Adjust ceiling hole and position of indoor unit (only 
for 2800-3600W type) 

Installation indicator 

 

Adjust  main  unit  position(only  for  4500-7100W 
type) 

Holder for remote controller 

Hold    the    remote controller 

Mounting screw(ST2.9x10-C-H) 

Insulation Holder for remote controller 

Screw  M4×16(including  flat  spring 
gasket) 

For fixing the installation pattern paper 
and panel(only for 2800-3600W type) 

Fixing belt 

10 

Fixing and tightening 

Straight pipe 

Drainage 

Elbow 

Connect drain pipe and straight pipe 

Big gasket 

Hang the indoor unit 

 
 

Содержание MDV-D18Q1/N1-D

Страница 1: ...SM 2014 06 1 One way Cassette Type 1 Features 2 2 Specifications 4 3 Dimensions 7 4 Service Spaces 9 5 Piping Diagrams 11 6 Wiring Diagrams 12 7 Capacity Tables 14 8 Electrical Characteristics 19 9 Sound Levels 20 10 Accessories 24 ...

Страница 2: ...pump are internally installed which means lower cost no extra accessories or installation time 1 4 Large airflow and low noise Large airflow for high ceiling application installation height can reach up to 3 2m guarantees comfort in large space 1 5 Improved air quality For capacity 1 8kW to 3 6 kW two folding type air filters and two standard formaldehyde absorption nets improve the air quality gr...

Страница 3: ...e adoption of this structure the guide wing will always wrapped up by dry cold air cutting off the contact route of moist hot air and the cold guide wing As a result the water vapour in mosit hot air gets no change to condense in the surface of guide wing 1 9 Auto restart When the indoor unit is powered off it will auto restart when powered on again after 3 minutes and operate in the previous stat...

Страница 4: ...Indoor noise level H M L dB A 37 34 30 38 34 30 Indoor unit Dimension W H D mm 1054 169 425 Packing W H D mm 1155 245 490 Net Gross weight kg 12 5 16 panel Dimension W H D mm 1180 36 5 465 Packing W H D mm 1232 107 517 Net Gross weight kg 3 5 5 2 Refrigerant type R410A Throttle Type Electrical expand valve Model D20MISZ 1R L Design pressure H L MPa 4 4 2 6 Refrigerant piping Liquid side Gas side m...

Страница 5: ...level H M L dB A 39 37 34 40 38 34 Indoor unit Dimension W H D mm 1054 169 425 Packing W H D mm 1155 245 490 Net Gross weight kg 13 16 5 panel Dimension W H D mm 1180 36 5 465 Packing W H D mm 1232 107 517 Net Gross weight Kg 3 5 5 2 Refrigerant type R410A Throttle Type Electrical expand valve Model D20MISZ 1R L Design pressure H L MPa 4 4 2 6 Refrigerant piping Liquid side Gas side mm Ф6 35 Ф12 7...

Страница 6: ...ise level H M L dB A 41 39 35 42 40 36 Indoor unit Dimension W H D mm 1147 200 640 Packing W H D mm 1380 265 775 Net Gross weight kg 31 5 37 2 31 5 37 2 panel Dimension W H D mm 1425 10 755 Packing W H D mm 1500 110 870 Net Gross weight kg 9 12 9 12 Refrigerant type R410A Throttle Type Electrical expand valve Model BD20FKS L Design pressure H L MPa 4 4 2 6 4 4 2 6 Refrigerant piping Liquid side Ga...

Страница 7: ... Cassette Type MCAC VTSM 2014 06 7 3 Dimensions MDV D18Q1 N1 D MDV D22Q1 N1 D MDV D28Q1 N1 D MDV D36Q1 N1 D Please use the installation paper plate to make sure the position of the installation screws 1015 290 ...

Страница 8: ...MCAC VTSM 2014 06 One way Cassette Type 8 MDV D45Q1 N1 C MDV D56Q1 N1 C ...

Страница 9: ...y air An unbearable place A place where high frequency waves are generated The appliance shall not be installed in the laundry Please comply with the related national eletric standard to make electric insulation for construction and metal parts of air conditioner Please choose the place where the ventilation is good Ceiling space repquires 153mm The installation height of the unit can not be highe...

Страница 10: ...MCAC VTSM 2014 06 One way Cassette Type 10 MDV D45Q1 N1 C MDV D56Q1 N1 C ...

Страница 11: ...te Type MCAC VTSM 2014 06 11 5 Piping Diagrams MDV D18Q1 N1 D MDV D22Q1 N1 D MDV D28Q1 N1 D MDV D36Q1 N1 D MDV D45Q1 N1 C MDV D56Q1 N1 C flare nut flare nut T2B gas side motor heat exchanger fan EXV liquid side T2 T1 ...

Страница 12: ...4500W 1 5HP T2 Mid pipe temp sensor of evaporator 4 5600W 2 0HP T2B Outlet temp sensor of evaporator 5 7100W 2 5HP XP1 3 Butt connection socket 6 8000W 3 0HP XS1 3 Butt connection socket 7 9000W 3 2HP TR Power transformer 8 11200W 4 0HP 9 14000W 5 0HP 1 The E heating component is optional not for all models 2 All dial code switches include HP switch cannot be adjusted by the user 3 Power wire fixe...

Страница 13: ...One way Cassette Type MCAC VTSM 2014 06 13 MDV D45Q1 N1 C MDV D56Q1 N1 C ...

Страница 14: ...1 46 0 1 2 1 1 1 5 1 2 1 7 1 2 1 8 1 2 1 8 1 2 1 9 1 1 1 9 1 1 2 2 10 0 1 5 1 3 1 8 1 4 2 1 1 5 2 2 1 5 2 3 1 6 2 6 1 6 2 9 1 5 12 0 1 5 1 3 1 8 1 4 2 1 1 5 2 2 1 5 2 3 1 6 2 6 1 6 2 8 1 5 14 0 1 5 1 3 1 8 1 4 2 1 1 5 2 2 1 5 2 3 1 6 2 6 1 6 2 8 1 5 16 0 1 5 1 3 1 8 1 4 2 1 1 5 2 2 1 5 2 3 1 6 2 6 1 6 2 8 1 5 18 0 1 5 1 3 1 8 1 4 2 1 1 5 2 2 1 5 2 3 1 6 2 6 1 6 2 8 1 4 20 0 1 5 1 3 1 8 1 4 2 1 1 5...

Страница 15: ... 4 2 3 3 6 2 4 3 8 2 5 4 1 2 3 4 2 2 2 27 0 2 5 1 9 2 9 2 1 3 4 2 3 3 6 2 4 3 8 2 5 4 0 2 2 4 2 2 2 29 0 2 5 1 9 2 9 2 1 3 4 2 3 3 6 2 4 3 8 2 5 4 0 2 2 4 1 2 2 31 0 2 5 1 9 2 9 2 1 3 4 2 3 3 6 2 4 3 8 2 5 4 2 2 6 4 1 2 2 33 0 2 5 1 9 2 9 2 1 3 4 2 3 3 6 2 4 3 8 2 5 4 2 2 6 3 9 2 1 35 0 2 5 1 9 2 9 2 1 3 4 2 3 3 6 2 4 3 8 2 5 4 2 2 6 3 9 2 1 37 0 2 5 1 9 2 9 2 1 3 4 2 3 3 6 2 4 3 7 2 4 3 8 2 3 3 9...

Страница 16: ...9 2 7 4 6 3 0 5 3 3 3 5 6 3 4 5 7 3 4 5 8 3 2 6 0 3 1 44 0 3 9 2 7 4 6 3 0 5 3 3 3 5 6 3 4 5 7 3 4 5 8 3 2 6 0 3 1 46 0 3 9 2 7 4 6 3 0 5 3 3 3 5 6 3 4 5 7 3 7 5 8 3 2 6 0 3 1 7 2 Heating TC total capacity WB wet bulb temperature DB dry bulb temperature Indoor Unit size kW Outdoor temperature Indoor temperature DB 16 00 18 00 20 00 21 00 22 00 24 00 TC TC TC TC TC TC WB DB kW kW kW kW kW kW 1 8 20...

Страница 17: ...3 5 60 5 00 2 21 2 21 2 21 2 21 2 21 2 21 3 70 3 00 2 32 2 32 2 32 2 32 2 32 2 32 0 70 0 00 2 49 2 49 2 49 2 49 2 49 2 35 2 20 3 00 2 63 2 63 2 63 2 63 2 58 2 35 4 10 5 00 2 72 2 72 2 72 2 72 2 58 2 35 6 00 7 00 2 80 2 80 2 80 2 72 2 58 2 35 7 90 9 00 2 88 2 88 2 80 2 72 2 58 2 35 9 80 11 00 2 97 2 97 2 80 2 72 2 58 2 35 11 80 13 00 3 08 3 02 2 80 2 72 2 58 2 35 13 70 15 00 3 16 3 02 2 80 2 72 2 5...

Страница 18: ...00 5 00 5 00 4 85 4 60 4 20 7 90 9 00 5 15 5 15 5 00 4 85 4 60 4 20 9 80 11 00 5 30 5 30 5 00 4 85 4 60 4 20 11 80 13 00 5 50 5 40 5 00 4 85 4 60 4 20 13 70 15 00 5 65 5 40 5 00 4 85 4 60 4 20 5 6 20 19 8 3 53 3 53 3 53 3 53 3 53 3 53 19 18 8 3 78 3 78 3 78 3 78 3 78 3 78 17 16 7 3 97 3 97 3 97 3 97 3 97 3 97 15 14 7 4 10 4 10 4 10 4 10 4 10 4 10 13 00 12 60 4 22 4 22 4 22 4 22 4 22 4 22 11 00 10 ...

Страница 19: ...0 135 MDV D22Q1 N1 D 50 220 240 198 242 0 169 15 0 012 0 135 MDV D28Q1 N1 D 50 220 240 198 242 0 178 15 0 012 0 142 MDV D36Q1 N1 D 50 220 240 198 242 0 178 15 0 012 0 142 MDV D45Q1 N1 C 50 220 240 198 242 0 56 15 0 055 0 45 MDV D56Q1 N1 C 50 220 240 198 242 0 51 15 0 055 0 41 Remark MCA Min Current Amps A MFA Max Fuse Amps A KW Fan Motor Rated Output kW FLA Full Load Amps A IFM Indoor Fan Motor ...

Страница 20: ...est condition ONE WAY CASSETTE TYPE Microphone 1 0m 9 2 Test value MDV D18Q1 N1 D Model Sound test value dB A H M L MDV D18Q1 N1 D 37 34 30 MDV D22Q1 N1 D 38 34 30 MDV D28Q1 N1 D 39 37 34 MDV D36Q1 N1 D 40 38 34 MDV D45Q1 N1 C 41 39 35 MDV D56Q1 N1 C 42 40 36 1 4m ...

Страница 21: ...One way Cassette Type MCAC VTSM 2014 06 21 MDV D22Q1 N1 D MDV D28Q1 N1 D ...

Страница 22: ...MCAC VTSM 2014 06 One way Cassette Type 22 MDV D36Q1 N1 D MDV D45Q1 N1 C ...

Страница 23: ...One way Cassette Type MCAC VTSM 2014 06 23 MDV D56Q1 N1 C ...

Страница 24: ...emotely controlling the unit Remote controller support 1 For placing the remote controller Battery 2 Battery for remote controller Cross recessed countersunk head self tapping screw 2 For fixing the remote controller support Small flathead screwdriver 1 Use for installing the wires and dial codes Copper 1 Use for pipe connection of engineering installation MDV D45Q1 N1 C MDV D56Q1 N1 C Name Quanti...