Midea MDDP-30DEN7-QA3 Скачать руководство пользователя страница 9

Removing the collected water

1. Pull out the bucket  a little.

2. Hold both sides of the bucket

with even strength, and pull it
out from the unit.

Fig.5

Fig.6

3. Pour the water out.

NOTES:

When you remove the bucket, do not touch any parts

inside of the unit. Doing so may damage the product.
Be sure to push the bucket gently all the way into the
unit. Banging the bucket against anything or failing to
push it in securely may cause the unit not to operate.
If the pump hose drops when you remove the bucket
(see Fig.7),you must reinstall the pump hose properly
to the unit before replace the bucket into the unit (see Fig.8).
When you remove the bucket,if there is some water in
the unit you must dry it.
When the unit is on, if the bucket is removed, the
compressor and the fan turn off, then the unit will beep
8 times and the digital display shows Eb.
When the unit is off, if the bucket is removed, the unit
will beep 8 times and the digital display shows Eb.

Fig.7

Fig.8

Pump hose
drops

Reinstall pump
hose properly

W hen using the unit

When first using the dehumidifier, operate the unit
continuously 24 hours.

This unit is designed to operate with a working
environment between 5 C/41 F and 32 C/90 F, and

O

O

O

O

between 30%(RH) and 80%(RH).
If the unit has been switched off and needs to be
switched on again quickly, allow approximately
three minutes for the correct operation to resume.
Do not connect the dehumidifier to a multiple socket
outlet, which is also being used for other electrical
appliances.
Select a suitable location, making sure you have easy
access to an electrical outlet.
Plug the unit into a  electrical socket-outlet with earth
connection.
Make sure the Water bucket is correctly fitted otherwise
the unit will not operate properly.

When the water in the bucket reaches to a certain

NOTE:

level,please be careful to move the machine to avoid it
falling down.

A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed

storage area, such as a closet, unless there is adequate circulation of air in and out of the area.

Positioning the unit

Do not use outdoors.
This dehumidifer is intended for indoor residential
applications only. This dehumidifier should not be used
for commercial or industrial applications.
Place the dehumidifier on a smooth, level floor strong
enough to support the unit with a full bucket of water.

Allow at least 20cm of air space on all sides of the unit

for good air circulation.
Place the unit in an area where the temperature will not
fall below 5 C(41 F). The coils can become covered with

O

O

frost at temperatures below 5 C(41 F), which may reduce

O

O

performance.
Place the unit away from the clothes dryer, heater or radiator.
Use the unit to prevent moisture damage anywhere books
or valuables are stored.
Use the dehumidifier in a basement to help prevent

moisture damage.

The dehumidifier must be operated in an enclosed
area to be most effective.
Close all doors, windows and other outside openings
to the room.

Fig.4a

20cm or more

20cm or more

40cm or more

20cm or more

40cm or
more

Air outlet grille

Casters(Install at four points on the
bottom of unit)

Do not force casters to move over
carpet, nor move the unit with water
in the bucket. (The unit may tip over
and spill water.)

NOTE:Casters is optional,some

models without.

14

15

OPERATING THE UNIT

IDENTIFICATION OF PARTS

There are three ways to remove collected water.
1. Use the bucket

When the bucket is full, the Full indicator light

will illuminate, the digital display shows P2.

Slowly pull out the bucket. Grip the left and right
handles securely, and carefully pull out straight so
water does not spill. Do not put the bucket on the floor
because the bottom of the bucket is uneven. Otherwise
the bucket will fall and cause the water to spill.
Throw away the water and replace the bucket. The
bucket must  be in place and securely seated  for the
dehumidifier to operate.
The machine will restore to its original state when the
bucket is replaced in its correct position.

Содержание MDDP-30DEN7-QA3

Страница 1: ...ior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the latest version GD MI...

Страница 2: ...ed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposa...

Страница 3: ...other foreign objects into grills or openings Take special care to warn children of these dangers Do not use in areas where chemicals are handled This will cause the unit deterioration due to chemical...

Страница 4: ...n Be aware that the refrigerants may not contain an odour Appliance should be installed operated and stored in a room with a floor area larger than 4 m 2 Compliance with national gas regulations shall...

Страница 5: ...ted This shall include damage to cables excessive number of connections terminals not made to original specification damage to seals incorrect fitting of glands etc Ensure that apparatus is mounted se...

Страница 6: ...mum working pressure of the cylinder even temporarily j When the cylinders have been filled correctly and the process completed make sure that the cylinders and preventing the ingress of flammable atm...

Страница 7: ...xits the Wireless connection mode automatically On Off Full Defrost Fig 1b High fan indicator light 10 11 NOTE The control panel of the unit you purchased may be slightly different according to the mo...

Страница 8: ...pad to change the Auto time by 0 5 hour incre ments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The selected time will register i...

Страница 9: ...sement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of the area Positioning the unit Do not use out...

Страница 10: ...emale threaded end is included Remove the plastic cover from the back drain outlet of the unit and set aside then insert the drain hose through the drain outlet of the unit and lead the drain hose to...

Страница 11: ...ash the filter with clean water then dry Re install the filter replace Bucket CAUTION DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce performance After t...

Страница 12: ......