background image

·  Water can be automatically emptied into a floor 

   drain by attaching the unit  with a water hose(not 

   included).

·  Remove the rubber plug or cut 

   the cover down from the back 

   drain hose outlet. Attach a 

   drain hose and lead it to the 

   floor drain or a suitable 

   drainage facility.  

·  Make sure the hose is secure

   so there are no leaks.

·  Direct the hose toward the drain,making sure that 

   there are no kinks that will stop the warter flowing.

·  Place the end of the hose into the drain and make 

   sure the end of the hose is level or down to let the 

   water flow smoothly. Do never let it up.

·  Make sure the water hose is lower than the drain 

   hose.

·  Select the desired humidity setting and fan speed

   on the unit for continuous draining to start. 

   

2. Continuous draining

Note: When the continuous drain feature is not 

being used,remove the drain hose  from the outlet 

and reinstall the rubber plug. 

     
 
    
    

Note:

·   When you remove the bucket, do not touch any 

    parts inside of the unit. Doing so may damage the 

    product. 

·   Be sure to push the bucket gently all the way into 

    the unit. Banging the bucket against anything or 

    failing to push it in securely may cause the unit 

    not to operate. 

·   When you remove the bucket, if there is some 

    water in the unit you must dry it.   

     
 
    

 

 Page 17

 Operating

Instructions

     

2. Hold both sides of the bucket with even strength, 

    and pull it out from the unit. 

3. Pour the water out.

    

    

Attach the hose to the drain

hose outlet.  

Remove the 

rubber plug

   

Содержание MDDF-16

Страница 1: ...DEHUMIDIFIER Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new machine Make sure to save this manual for future reference...

Страница 2: ...ance Table of Contents Control Panel Features 12 Other features 15 Clean the grille and case 18 Clean the bucket 18 Troubleshooting Tips 19 Clean the air filter 18 When not using the unit for long tim...

Страница 3: ...the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during oper...

Страница 4: ...been damaged contact a technician or customer service for assistance In a thunderstorm the power must be cut o to avoid damage to the machine due to lightning Do not run cord under carpeting Do not c...

Страница 5: ...of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities When using this dehu...

Страница 6: ...manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants The appl...

Страница 7: ...able material 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flamma...

Страница 8: ...supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing t...

Страница 9: ...ions on the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 10 Detection of flammable refrigerants The fo...

Страница 10: ...g order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered r...

Страница 11: ...prior notice Preparation rear front rear front rear front control panel control panel shoes dryer cover shoes dryer pipe drain hose outlet drain hose outlet drain hose outlet power cord buckle power c...

Страница 12: ...to help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room A dehumidifier operating in a...

Страница 13: ...s Then press pad to operate the desired settings For panel H Indicator Function Indicator Function Timer ON light Timer OFF light Bucket full light Air purifier light Low fan speed light Med fan speed...

Страница 14: ...fan control to Normal Note The turbo button is disabled in Dryer mode the Self clean Air purifier or Anti mould functions Pressing the turbo button for more than 3 seconds enables the Self clean funct...

Страница 15: ...midity sensor error Unplug the unit and plug it back in If error repeats call for service ES Temperature sensor error Unplug the unit and plug it back in If error repeats call for service P2 Bucket is...

Страница 16: ...on will also be cancelled There are two ways to remove collected water 1 Use the bucket When the unit is off if the bucket is full the unit will beep 8 times on some models and the Full Water indicato...

Страница 17: ...the drain hose Select the desired humidity setting and fan speed on the unit for continuous draining to start 2 Continuous draining Note When the continuous drain feature is not being used remove the...

Страница 18: ...urely seated for the dehumidifier to operate The air filter behind the front grille should be checked and cleaned at least every two weeks or more often if necessary NOTE DO NOT RINSE OR PUT THE FILTE...

Страница 19: ...upright as it should be The floor surface is not level Hose to connector or hose connection may be loose Intend to use the bucket to collect water but the back drain plug is removed This is normal The...

Страница 20: ...s are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please...

Отзывы: