![Midea MBSFI-A1-1511 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/midea/mbsfi-a1-1511/mbsfi-a1-1511_service-manual_1790741026.webp)
T1-Td+ΔT
7.4.3.4Defrosting mode
AC will enter the defrosting mode according to
the value of temp. of T3 and the value range of
temp. change of T3 and also the compressor
running time.
During the defrosting mode, the compressor
keep running, indoor and outdoor motor will stop,
defrost lamp of the indoor unit will be lighted
“
.
” Will be displayed.
7.4.3.5 Evaporator coil temperature
protection
T2
Resume
Off
Decrease
Hold
When evaporator temperature temp. is more
than
the
setting
protection
value,
the
compressor will stop.
7.4.4 Auto-mode
This mode can be chosen with remote
controller and the setting temperature can be
changed between 17°C~30°C
In auto mode, the machine will choose cooling,
heating or fan-
only mode according to ΔT (ΔT
=T1-Ts).
T1-Ts
Cooling
Heating*
Fan only
Indoor fan will run at auto fan of the relevant
mode.
The louver operates same as in relevant mode.
If the machine switches mode between heating
and cooling, the compressor will keep stopping
for certain time and then choose mode
according to T1-Ts.
If the setting temperature is modified, the
machine will choose running function again.
7.4.5 Drying mode
Indoor fan speed is fixed at breeze and can’t be
changed. The louver angle is the same as in
cooling mode.
All protections are active and the same as that
in cooling mode.
7.4.6 Forced operation function
Forced cooling mode:
The compressor and outdoor fan keep running
and the indoor fan runs at low speed. After
running for 30 minutes, AC will turn to auto
mode with 24
℃
setting temperature.
Forced auto mode:
The action of forced auto mode is the same as
normal
auto
mode
with
24
℃
setting
temperature.
When AC receives signals, such as switch on,
switch off, timer on, timer off, mode setting, fan
speed setting, sleeping mode setting, follow me
setting, it will quit the forced operation.
Содержание MBSFI-A1-1511
Страница 1: ...Mission 3D Inverter Series Service Manual 2014 MBSEU A 1412...
Страница 9: ......
Страница 11: ...For MOB01 09HFN1 QRD0GW MOB01 12HFN1 QRD0GW MOB01 18HFN1 QRD0GW...
Страница 12: ...For MOF2 24HFN1 QRD0GW Model W D H W1 A B MOF2 24HFN1 QRD0GW 845 320 700 908 560 335...
Страница 20: ...Be sure to check for gas leakage...