Service manual
DM16-01.01.11-01en
8
Multi DC inverter R410A. Outdoor unit
Outdoor Model
M4OB-36HFN1-Q
Indoor unit combination
Single
Double
Three
Four
Power supply
V-ph-Hz
220-240V- 50Hz, 1Ph
Cooling
Capacity
Btu/h
7000-18000 14000-26000 21000-36000 36000
Input
W
1250-1700
1650-2320
2150-3520
3505
Rated current
A
5.4-7.4
7.2-10.1
9.3-15.3
15,2
EER
W/W
/
/
/
3,01
Heating
Capacity
Btu/h
7000-20000 16000-29000 24000-38000 38000
Input
W
1375-2440
2050-3340
2880-3360
3266
Rated current
A
5.9-10.6
8.9-14.5
12.5-14.6
14,2
COP
W/W
/
/
/
3,41
Max. input consumption
W
4600
Max. input current
A
21.5
Compressor
Model
ATF310D43UMT
Type
ROTARY
Brand
GMCC
Capacity
Btu/h
32380
Input
W
2600
Rated current(RLA)
A
5,1
Locked rotor Amp(LRA)
A
-----
Thermal protector position
INTERNAL
Capacitor
μ
F -----
Refrigerant oil
ml
PQE(VG74)/1000
Outdoor fan
motor
New Model
ZKFN-120-8-2
Model
WZDK120-38G-W
Qty
1
Output W
120(Output)
Capacitor
μ
F -----
Speed(Hi/Med/Lo) r/min
900
Outdoor coil
Number of rows
2
Tube pitch(a)* row pitch(b)
mm
25.4x22
Fin spacing
mm
1.3
Fin type
Hydrophilic aluminium
Tube outside dia.and type
mm
Ф
9.52, innergroove tube
Coil length * height * width
mm
995x762x44
Number of circuits
4
Outdoor air flow
m3/h
5500
Outdoor sound pressure level
dB(A)
63.5
Throttle type
CaEXV
Outdoor unit
Dimension(WxDxH) mm
946x410x810
Packing(WxDxH) mm
1090x500x865
Net/Gross weight
kg
70/75
Refrigerant
Type
R410A
GWP
2088
Charged quantity
Kg
3
Design pressure
MPa
4.2/1.5
Refrigerant
piping
Liquid side/ Gas side
mm(inch)
4 x
Φ
6.35/3x
Φ
9.52+1x
Φ
12.7(4x1/4"/3x3/8"+1x1/2")
Max. length for all rooms
m
60
Max. length for one indoor unit
m
30
Max. height difference
between indoor and outdoor
unit
OU higher than
IU
m 10
OU lower than
IU
m 15
Max. height difference between indoor units
m
10
Ambient
temperature
Cooling
℃
-15-50
Heating
℃
-15-24
1.The above design and specifications are subject to change without prior notice for product improvement.
2.The values given in the table for the noise level reflect the levels in hemi-anechoic rooms.