background image

3

INDOOR UNIT

OUTDOOR UNIT

DISPLAY PANEL

Air outlet

Air outlet

Air inlet

TIMER

RUN

DEF.

Air inlet

3

10

11

12

8

7

4

5

6

9

2

1

DISPLAY PANEL

INDOOR UNIT

Front panel frame

Front panel

Air filter

Horizontal air flow grille

Vertical air flow louver

Room temperature sensor

Display panel

Infrared signal receiver

Remote controller

Drain hose, refrigerant connecting pipe

Connective cable

Stop valve

OPERATION/RUN indicator:

TIMER indicator:

PRE-DEF./DEF. Indicator

AUTO indicator:

The indicator flashes once every second
after power is on and illuminates when the
air conditioner is in operation.

The indicator illuminates when TIMER is set ON.

:

This indicator flashes when the air conditioner
is in AUTO operation.

(For cooling& heating model only)

This indicator illuminates when the air conditioner
starts defrosting automatically or when the Anti-
cold air feature is activated in heating operation.

1

3

4

5

6

7

8

9

10

11

12

2

Infrared signal receptor

OPERATION

TIMER

PRE-DEF

AUTO

Infrared signal receptor

NOTE:

The display panel on the indoor unit
would look like one of following:

Note:

All the pictures in this manual are for explanation
purpose only. They may be slightly different from
the air conditioner you purchased. The actual
shape shall prevail.

PARTS NAMES

AUTO

Содержание Inverter Split-type Room Air Conditioner

Страница 1: ...Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner OWNER S MANUAL Inverter Split type Room Air Conditioner...

Страница 2: ...tablished collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of char...

Страница 3: ...ms in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service Contact an authorised service technician for repair or maintenance of...

Страница 4: ...earthing may cause electric shock It may cause fire and electric shock There is risk of fire or electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat gen...

Страница 5: ...nts and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not sing the unit for a long t...

Страница 6: ...and illuminates when the air conditioner is in operation The indicator illuminates when TIMER is set ON This indicator flashes when the air conditioner is in AUTO operation For cooling heating model...

Страница 7: ...N 1 3 2 NOTE The unit must be turned off before operating the manual control button If the unit is operational continue pressing the manual control button until the unit is off Mode Cooling operation...

Страница 8: ...desired position To set the horizontal air flow direction left right The DIRECTION SWING button will be disabled when the air conditioner is not in operation including when the TIMER is set Do not ope...

Страница 9: ...olled under dry operation During the dry operation if the room temperature is lower than 10 C the compressor stops operation and restarts until the room temperature is above 12 C O O To achieve optima...

Страница 10: ...fore cleaning WARNING Filter Handle 7 Use a dry cloth to wipe the indoor unit and controller A cloth dampened with cold water may be used the indoor unit if it is very dirty The front panel of the ind...

Страница 11: ...juries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock When cleaning the...

Страница 12: ...enerate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 You may hear a low hissing sound when the compressor is running or...

Страница 13: ...e can t be achieved conditioner we suggest you use a supplementary heating device 9 Power failure during operation will stop the unit completely For the unit without Auto restart feature when the powe...

Страница 14: ...wn Battery in Remote controller may have been exhausted The time you have set with timer is incorrect Wait for power to be restored Check that plug is securely in wall receptacle Replace the fuse Repl...

Страница 15: ...CS383 U1 202000190149 20100630 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...