29
3% per degree centigrade. Sensor used in the refrigerator is NTC thermistor.
There is following computing formula for the sensor:
Sampling voltage / reference voltage = R1 / (RNTC + R1)
AD value / reference AD value = R1 / (RNTC + R1)
The reference voltage is 5V, RNTC is the resistance value of the sensor, R1 is R31\R32\R33 in
schematic diagram that is 5.1K
10.4
Fan motor circuit of the freezing chamber
The fan in the freezing chamber is running when the compressor is operating. Check 12V and
FAN to see if there is a voltage of 12V. When in normal operation, the fan is in low level and the
voltage between 12V and FAN is more than 11V. If there’s no voltage when the compressor is in
operation, fan motor or electric control panel can be replaced.
10.5
Refrigerator fan motor circuit (None)
10.6
Condensing fan motor circuit (None)
10.7
Damper motor circuit (None)
10.8
Resistance value of the sensor (R/T)
Tx(
℃
)
R
(
KΩ
)
Tx(
℃
)
R
(
KΩ
)
Tx(
℃
)
R
(
KΩ
)
Tx(
℃
)
R
(
KΩ
)
Tx(
℃
)
R
(
KΩ
)
-30
33.81
-15
14.31
0
6.495
15
3.141
30
1.617
-29
31.85
-14
13.55
1
6.175
16
2.999
31
1.55
-28
30.01
-13
12.83
2
5.873
17
2.865
32
1.486
-27
28.29
-12
12.16
3
5.587
18
2.737
33
1.426
-26
26.68
-11
11.52
4
5.315
19
2.616
34
1.368
Содержание HS-455LWEN-W1
Страница 1: ...REFRIGERATOR MODEL HS 455LWEN D W1 Instruction Manual...
Страница 5: ...1 1 Safety Warning Code 1 1Warning for operation safety...
Страница 6: ...2...
Страница 7: ...3...
Страница 8: ...4 1 2Safety instruction for refrigerant...
Страница 16: ...12 Defrosting heater in freezing chamber 5 5Circuit diagram...
Страница 35: ...31 11 Troubleshooting Method 11 1 No refrigeration...
Страница 36: ...32 11 2 Compressor failure 11 3 Undercooling Electronic temperature control...
Страница 37: ...33 11 4 Fan failure 11 5Noise...
Страница 38: ...34 11 6 Lights inside the refrigerator don t light up...
Страница 43: ...39 5 Sealing tape door fixing for reversible door option...
Страница 44: ......