Ins
tallation

Ins
tructions

3

Installation Instructions

Your installation location should meet the following 
requirements:

• Make sure that you install your unit on an even surface

to minimize noise and vibration.

• The unit must be installed near a grounded plug, and

the Collection Tray Drain (found on the back of the
unit) must be accessible.

• The unit should be located at least 30 cm (12”) from

the nearest wall to ensure proper air conditioning.

• DO NOT cover the Intakes, Outlets or Remote Signal

Receptor of the unit, as this could cause damage to
the unit.

Choosing the Right Location

30 cm

12 inch

12 inch

30 cm

Note About Fluorinated Gasses

• This air-conditioning unit is a hermetically sealed unit that contains fluorinated

gasses. For specific information on the type of gas and the amount, please refer to
the relevant label on the unit itself.

• Installation, service, maintenance and repair of this unit must be performed by a

certified technician.

• Product uninstallation and recycling must be performed by a certified technician.

• If the system has a leak-detection system installed, it must be checked for leaks at

least every 12 months.

• When the unit is checked for leaks, proper record-keeping of all checks is strongly

recommended.

NOTE

All the illustrations in the 

m

anual are for explanation purpose only. Your 

m

achine 

m

ay be slightly different.

The actual shape shall prevail.

The unit can be controlled by the unit control panel alone or with the re

m

ote 

controller. This 

m

anual does not include Re

m

ote Controller Operations, see the 

<<Re

m

ote Controller Instruction>> packed with the unit for details.

Содержание EasyCool MPF08CR81-E

Страница 1: ...ad this manual carefully and keep it for future reference The design and specifications are subject to change without prior notice for product improvement Consult with your dealer or manufacturer for...

Страница 2: ...this product Contact the authorized service technician for repair or maintenance of this unit The air conditioner is not intended for use by young children or infirm persons without supervision Young...

Страница 3: ...ate voltage The power cord is equipped with a three prong grounding plug to protect against shock Voltage information can be found on the side of the unit behind the grille Install the unit in on a fl...

Страница 4: ...or their safety be applicable for other countries except the European Countries Children should be supervised to ensure that they do not play with the appliance If the supply cord is damaged it must b...

Страница 5: ...ront Control panel Handle both sides Horizontal louver blade Caster Power plug socket Power cord buckle Bottom tray drain outlet Power cord outlet Drain outlet only for pump heating mode Upper air fil...

Страница 6: ...ubject to change without prior notice Energy Rating Information The Energy Rating for this unit is based on an installation using an un extended exhaust duct without adapters A or B as shown in the In...

Страница 7: ...uminates This feature is a reminder to clean the Air Filter for more efficient operation Press this button for 3 seconds to cancel the reminder Timer button Used to initiate the AUTO ON start time and...

Страница 8: ...Error codes and protection code E1 Room temperature sensor error E2 Evaporator temperature sensor error E3 Condenser temperature sensor error on some models E4 Display panel communication error E7 Zer...

Страница 9: ...minates Press the UP or down button to select the desired time Press the TIMER button again within 5 seconds the Auto on start program is initiated And the TIMER ON indicator light illuminates Press t...

Страница 10: ...ous function setting automatically when the power resumes WAIT 3 MINUTES BEFORE RESUMING OPERATION After the unit has stopped it can not be restarted operation in the first 3 minutes This is to protec...

Страница 11: ...e is secure so there are no leaks Direct the hose toward the drain making sure that there are no kinks that will stop the water flowing Place the end of the hose into the drain and make sure the end o...

Страница 12: ...nit that contains fluorinated gasses For specific information on the type of gas and the amount please refer to the relevant label on the unit itself Installation service maintenance and repair of thi...

Страница 13: ...t adaptor Window slider adaptor Window slider A Window slider B Exhaust hose Bolt Foam seal A adhesive Foam seal B adhesive Foam seal C Non adhesive Security bracket and 2 screws Drain hose Drain hose...

Страница 14: ...he Exhaust hose assembly along the arrow direction for installation Step Three Preparing the adjustable window slider 1 Depending on the size of your window adjust the size of the window slider 2 If t...

Страница 15: ...am seal A Adhesive type Window slider A Window slider B if required Foam seal C Non adhesive type Security Bracket 2 Screws Installation Instructions 2 Insert the window slider assembly into the windo...

Страница 16: ...trip to match the window height Insert the foam seal between the glass and the window frame to prevent air and insects from getting into the room 4 If desired install the security bracket with 2 screw...

Страница 17: ...ly was damaged during cleaning A damaged power cord must be replaced with a new cord from the manufacturer Clean the unit using a damp lint free cloth and mild detergent Dry the unit with a dry lint f...

Страница 18: ...r is blocked Turn off the unit disconnect the hose check for blockage and reconnect the hose The unit is low on refrigerant Call a service technician to inspect the unit and top off refrigerant Temper...

Страница 19: ...Functions for instructions LED Turns indoor unit s LED display on and off If you are sensitive to light when you go to sleep you can press the LED button to turn off the LED display on the unit Press...

Страница 20: ...r disposal of batteries TIPS FOR USING REMOTE CONTROL The remote control must be used within 8 meters 26 feet of the unit The unit will beep when remote signal is received Curtains other materials and...

Страница 21: ...display Displays when SLEEP function is activated SILENT display Not available for this unit FAN SPEED display Displays selected FAN SPEED HIGH MED LOW This display is blank when set to AUTO speed Tem...

Страница 22: ...tton 3 Press the button to start the unit NOTE FAN SPEED can t be set in AUTO mode COOL operation 1 Press the button to select COOL mode 2 Set your desired temperature using the temperature or tempera...

Страница 23: ...AT operation 1 Press the button to select HEAT mode 2 Set your desired temperature using the temperature or temperature button 3 Press the button to select the fan speed AUTO LOW MED or HIGH 4 Press t...

Страница 24: ...t of time after the current time that you want the unit to turn on For example if you set TIMER ON for 2 hours 2 0h will appear on the screen and the unit will turn on after 2 hours 2 Press the button...

Страница 25: ...T CU T TIME R ON TE MP sec 8 1 X12 2 5 X16 6 3 7 Setting both TIMER ON and TIMER OFF at the sa me time Keep in mind that the time periods you set for both functions refer to hours after the current ti...

Страница 26: ...rrent operation settings including operating mode setting temperature fan speed level and sleep feature if activated How to Use the Advanced Functions SLEEP Function The sleep function is used to decr...

Страница 27: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio...

Страница 28: ...CjAidea make yourself at home...

Отзывы: