2 Factory Pattern Detection
When the machine work normal,we can check as follow :
Press water level key and power off key ,enter into whole show model
(C1), all light of, the PCB show ;
Press water level key again, enter into wash model (C2), Impeller turn;
Press water level key again, enter into spin model, Retractor work,start
drain (C3), Tub start turn;
Press water level key again, enter into whole show model again;
Such circulate.
3
UNPACKING WAYS OF MAIN PARTS
ITEM
PICTURE
HOW TO DISASSEMBLE
1.BACK COVER Use cross
screwdriver
①Unscrew the screws on
the back cover ( Red circle
part) and then take out the
rear cover.
①Unscrew the earth screws
tomake the earth wire
subassembly and cabinet
separate.
②Unscrew the capacitor
screws,take down capacitor
catch.
③Pull out the air pipe to
make the air pipe and
suspend poles separate
(When you install the air
pipe, you remember to
coat adhesive for
preventing leakage
2. The earth
screws,capacitor screws,
and then pull out the air
pipe.( make the air pipe
and suspend poles
separate)Use cross
screwdriver