76
3
Electrical
parts
How to remove the
electrical parts.
1) After finish work of
item 1 and item 2, remove
the connector for the
compressor
2) Pull out the two blue
wires connected with the
four way valve.
3) Pull out connectors of
the, condenser coil temp.
sensor(T3),outdoor
ambient temp. sensor(T4)
and discharge temp.
sensor(TP).
○
1
○
2
○
3