![Midea CE-BD138- FT Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/midea/ce-bd138-ft/ce-bd138-ft_service-manual_1791129025.webp)
Service Manual_2018-V1.0
25
11
)
Vacuum system,The degree of vacuum below 6Pa.
12
)
Perfusion refrigerant.
13
)
Use the vise grip pliers
clamp the middle of the
process pipe, then seal welding process tube
⓯⓰
.
Piping system in the compressor case
❶
Capacitor
❷
-
1 Front condenser pipeline-1
❸
-
2 Rear condenser pipeline-2
❹
-
1Anti-dew pipe-1
❺
Temperature-control box assembly
❻
Drying filter
❼
Capillary
❽
Protective cover
❾
Wires
❿
Compressor
⓫
Suction Pipe
⓬
-
1 Rear condenser pipeline-1
⓭
-
2 Front condenser pipeline-2
⓮
-
2Anti-dew pipe-2
⓯
Compressor Assembly Board
Содержание CE-BD138- FT
Страница 12: ...Service Manual_2018 V1 0 12 4 Terms 4 1 Definition of model None 4 2 Location of nameplate None...
Страница 15: ...Service Manual_2018 V1 0 15 5 5 Circuit diagram...
Страница 32: ...Service Manual_2018 V1 0 32 11 Troubleshooting Method 11 1 Not cooling...
Страница 33: ...Service Manual_2018 V1 0 33 11 2 Not working of compressor 11 3 Thermostat malfunction Undercooling...
Страница 34: ...Service Manual_2018 V1 0 34 11 4 Light is not on 11 5 Noise...