Service Manual_2017-V1
33
9.4 Control of standby function
9.5 Control of ice maker (None)
9.6 Fault code and solutions
Fault code
Display
Failure Type
Solution
E1
“On” of LED1
and LED2
simultaneously
Temperature
sensor fault in
refrigerating
chamber
Step 1: Check whether the terminal CN3 is well stuck,
pull out the terminal and re-stick it in place
Step 2: Check to see if there are foreign matters on
the terminal. Pull out the refrigerating sensor
according to the method in described in Article 8.5
and then inspect the sensor against the resistance
value table in 10.8.
Step 3: Replace main control board
Step 4: Replace electrical wiring main harness
E5
“On” of LED1
and LED3
simultaneously
Fault of F
defrost sensor
Step 1: Check whether the terminal CN3 is well stuck,
pull out the terminal and re-stick it in place
Step 2: Check to see if there are foreign matters on
the terminal. Pull out the defrost sensor in freezing
chamber according to the method in described in
Article 8.5 and then inspect the sensor against the
resistance value table in 10.8.
Step 3: Replace main control board
Step 4: Replace electrical wiring main harness
E7
“On” of LED1
and LED4
simultaneously
Ambient
temperature
sensor fault
Step 1: Check whether the terminal CN3 of main
control board is well stuck, pull out the terminal and
re-stick it in place
Step 2: Check to see if the
re’re foreign matters on the
terminal. Pull out the defrost sensor in freezing
chamber according to the method in described in
Article 8.5 and then inspect the sensor against the
resistance value table in 10.8.
Step 3: Replace main control board
Step 4: Replace electrical wiring main harness
9.7 Defrosting function
1.Defrost the freezing chamber as per the accumulative operation time of the Compressor2.If power
failure occurs abruptly to the Compressor and the defrosting sensor in freezing chamber is less than 0
o
C
after powering on, then first conduct defrosting once. If more than 0
o
C
, then defrosting is not needed.
After that, conduct defrosting according to using condition and ambient temperature in a period between 6
and 24 hours as per the accumulative operation time of the Compressor.
9.8 Test mode
Test items
Testing Method
Expected result
Enter Test
Mode
Keep pressing the SET button
for 15 seconds and release
LED indicators on Gear 1, 2, 3, 4 and 5 light up
and flicker in the frequency of 0.5s, then the
refrigerator enters into test mode
After entering into test mode, if
then the refrigerator will exit the test mode and
Содержание 22031020001681
Страница 14: ...Service Manual_2017 V1 14 4 Terms 4 1 Definition of model None 4 2 Location of nameplate None ...
Страница 20: ...Service Manual_2017 V1 20 7 2 Circulating route of cooling air ...
Страница 38: ...Service Manual_2017 V1 38 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic ...
Страница 39: ...Service Manual_2017 V1 39 11 2 No working of compressor 11 3 Inside frosting no defrosting ...
Страница 40: ...Service Manual_2017 V1 40 11 4 Inside frosting no defrosting Maintenance guidelines ...
Страница 41: ...Service Manual_2017 V1 41 11 5 Light is not on 11 6 Air duct not operated electronically None 11 7 Fan failure ...
Страница 42: ...Service Manual_2017 V1 42 11 8 Defective defrost circuit 11 9 Noise ...
Страница 47: ...Service Manual_2017 V1 47 7 Transition copper pipe Aluminium Aluminium tubes welding maintain lengthen tubes ...