INSTALLATION AND OPERATION MANUAL, 

ELECTRIC CABINET BASE CONVECTION STEAMER, MODELS ECX-2, ECX-10

PART NUMBER 10058R2

14

2008-11-12

TO CALIBRATE PRESSURE SWITCHES

Pressure switch range is from 1 to 15 psi.

Adjust all settings to maximum on high signal adjustment screw on pressure switches.

Adjust in the following sequence:

- High limit pressure switch.  
- Override pressure switch.
- Operating pressure switch.
- Turning screw clockwise to increase, counterclockwise to decrease pressure. 
- Use relief valve to release pressure from boiler for setting adjustments.

1. HIGH LIMIT PRESSURE SWITCHES

Allow pressure to build until unit shuts off.  This should occur at 15 psi.  Set the high signal
to switch at 14.5 psi on the gauge and the low signal to 13.0 psi.

2. OVERRIDE PRESSURE SWITCHES

Allow pressure to increase to 13 psi.  Set the high signal to switch at 13 psi on the gauge
and the low signal to 11 psi.

3.  OPERATING PRESSURE SWITCHES

Set the high signal to switch at 11 psi on the gauge and the low signal to 9 psi.

4. Release pressure in boiler to below 9 psi.  Elements will come on.  Once pressure has

reached 11 psi, elements will shut off.  Repeat this process several times to make sure
elements come on at 9 psi and shut off at 11 psi.

Once completed, pressure switches have been calibrated.

Should your unit not have the High Limit pressure switch, start procedure at Override pressure
switch.  

SERVICE

Contact your local authorized service office for any repairs or adjustments needed on this
equipment.

NOTE:  Pressure switches are factory set.  Calibration is only required if

pressure switches are replaced or if adjustment is required.  

Содержание Crown ECX-10

Страница 1: ...e instructions thoroughly before installing or servicing this equipment IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment Model _____...

Страница 2: ...oid possible injury or death WARNING Improper installation operation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintena...

Страница 3: ...AMER MODELS ECX 2 ECX 10 PART NUMBER 10058R2 3 2008 11 12 TABLE OF CONTENTS DESCRIPTION PAGE Important Notes 2 1 0 Service Connections 4 2 0 Installation Instructions 5 3 0 Operating Instructions 6 4...

Страница 4: ...INSTALLATION AND OPERATION MANUAL ELECTRIC CABINET BASE CONVECTION STEAMER MODELS ECX 2 ECX 10 PART NUMBER 10058R2 4 2008 11 12 1 0 SERVICE CONNECTIONS...

Страница 5: ...arked on floor and insert proper anchoring devices 5 Set unit back in position and re level left to right and front to back 6 Bolt and anchor appliance securely to the floor 7 Seal bolts and flanged f...

Страница 6: ...vel has reached the proper operating level as indicated on water gauge glass the heating elements will be energized and heat the water When steam pressure has reached 11 psi the elements will de energ...

Страница 7: ...9 0 psi the pressure switch closes energizing the elements Condensing Drain Optional A thermostat is located in the drain assembly and is activated by the temperature of steam The thermostat operates...

Страница 8: ...alve will open Low Water Condition Standard Controls A low water safety cut off is supplied with the boiler Should the water level fall below normal operating levels the boiler will shut down If the w...

Страница 9: ...d into compartment and shut door 5 Set timer to cooking time desired Cooking cycle may be interrupted at any time by opening door and resumed again by closing door 6 When buzzer sounds it indicates th...

Страница 10: ...set timers to their OFF position and leave doors slightly open 2 At the end of the day the steam supply must be shut off Open the door of cabinet base and turn off power switch Open manual drain valve...

Страница 11: ...on your boiler requires periodic maintenance As boiler water circulates into the float chamber sand scale and other sediment may be deposited in the float chamber While the chamber has been designed w...

Страница 12: ...a plastic bottle brush and mild detergent clean inside the drain opening ensuring there is no food residue or blockage Clean the drain screen and replace in its original position 4 Wash gasket sealing...

Страница 13: ...half gallon US of CLR Descaling Solution or use the Optional Deliming Assembly DPA 1 available from your dealer 4 Replace 3 4 pipe plug securely 5 Open water supply to appliance allowing water to fil...

Страница 14: ...and the low signal to 13 0 psi 2 OVERRIDE PRESSURE SWITCHES Allow pressure to increase to 13 psi Set the high signal to switch at 13 psi on the gauge and the low signal to 11 psi 3 OPERATING PRESSURE...

Страница 15: ...e water fill solenoid 3 Water level control clogged or defective unable to operate fill valve 4 Check drain valve is closed Also check that water level control valve is closed 5 Supply water pressure...

Страница 16: ...SOLID PANS PRODUCT TIMER SETTING IN MINUTES WEIGHT PER PAN Eggs Scrambled 10 12 8 Dozen Rice Long Grain Cover with 4 cups water lb 25 2 Lb Pasta Place perforated pan inside solid pan cover pasta with...

Страница 17: ...0 Lb 4 Per Pan Salmon Fillets Frozen 8 oz Each 5 7 Lb Scallops Fresh 4 3 Lb Scrod Fillets Fresh 3 5 4 Lb Eggs Hard Cooked Soft Cooked Soft Yoke for Caesar Salad 15 9 10 6 8 4 Dozen 4 Dozen 4 Dozen Chi...

Страница 18: ...1 7 Lb 4 Lb 9 Lb Cauliflower Florets Frozen Fresh 6 7 8 4 Lb 5 Lb Celery 1 Diagonal Cut 7 5 Lb Corn Yellow Whole Kernel Frozen Cobbettes Frozen Corn On Cob Fresh 5 8 16 18 10 12 16 18 5 Lb 27 Ears 80...

Страница 19: ...s Do not allow food to protrude above pans since this will interfere with steam circulation between pans in the compartment Always preheat compartments for satisfactory results When time does not allo...

Отзывы: