SECTION 3
OPERATION
37
previously used set temperature will appear when the
oven is turned ON again.
Adjusting the Belt Time
To adjust the belt time, press and hold the
button until the belt time display flashes. Press the
or
button until the desired belt time is
displayed. Press the
button to set and save the
new time value. If the
button is not pressed, the
new time will be present only until the oven is turned
OFF. The previously used belt time will appear when
the oven is turned ON again.
Daily Shutdown Procedure (Turning the Oven
Off)
To turn the oven OFF, press and hold the
button. If the oven is below 200°F the display will show
the “WOW OVEN” screen. If the oven is above 200°F,
the display will show “COOL DOWN” and the blowers
will run at a preset cool down speed until the oven
temperature fails below 200°F at which point the oven
will go to the OFF mode. In the OFF mode, the screen
will display the “WOW OVEN” screen for a one minute
period after which the screen backlight will shut off.
The oven will stay in this condition until it is started
again, with no outputs energized.
III. PROGRAMMING INSTRUCTIONS
(MANAGERS MODE)
Changing Baking Blower Speeds (Run Mode)
To change the upper or lower blower speeds without
turning the oven OFF:
1. Enter the BLOWER CONFIGURATION Screen.
Press and hold
key until “PASSWORD”
appears on the screen. Press
and
. The screen should
appear as below.
PS360E/PS360EW Display
2. Press
until UPPER HIGH HZ is flashing.
Press
to change UPPER HIGH HZ. Press
or
to display the desired value.
Press
to accept the new value. Follow same
procedure for the LOWER HIGH HZ value if
required.
−
MINIMUM HZ VALUE: 50 Hz
−
MAXIMUM HZ VALUE: 90 Hz
Changing Energy Mode Status (Run Mode)
If the photo eye should ever fail to operate, baking
mode can be continually engaged by disabling the
energy mode. A service call should be made in the
interim, as energy use will be considerably higher
without the energy mode.
Press
until ENERGY MODE is flashing. Press
. Status of energy mode will be flashing (i.e.,
YES or NO). Press
to change status to desired
state. Press
to accept status change. Press
to leave the BLOWER CONFIGURATION
screen.
Содержание PS360E Series
Страница 8: ...SECTION 1 DESCRIPTION 8 III DIMENSIONS...
Страница 9: ...SECTION 1 DESCRIPTION 9...
Страница 34: ...SECTION 2 INSTALLATION 34 NOTES...
Страница 44: ...SECTION 4 MAINTENANCE 44...
Страница 48: ...SECTION 6 ELECTRICAL SCHEMATICS 48 Wiring Diagram E208 240 V 30kW PS360E 75938 REV B Sheet 2 of 2...
Страница 49: ...SECTION 6 ELECTRICAL SCHEMATICS 49 Wiring Diagram E380 V 30kW PS360E CE 75781 REV B Sheet 1 of 2...
Страница 50: ...SECTION 6 ELECTRICAL SCHEMATICS 50 Wiring Diagram E380 V 30kW PS360E CE 75781 REV B Sheet 2 of 2...
Страница 51: ...SECTION 6 ELECTRICAL SCHEMATICS 51 Wiring Diagram E380 V 30kW PS360E Non CE 78144 REV B Sheet 1 of 2...
Страница 52: ...SECTION 6 ELECTRICAL SCHEMATICS 52 Wiring Diagram E380 V 30kW PS360E Non CE 78144 REV B Sheet 2 of 2...
Страница 53: ...SECTION 6 ELECTRICAL SCHEMATICS 53 Wiring Diagram E208 240 V 36kW PS360EW 78141 REV B Sheet 1 of 2...
Страница 54: ...SECTION 6 ELECTRICAL SCHEMATICS 54 Wiring Diagram E208 240 V 36kW PS360EW 78141 REV B Sheet 2 of 2...
Страница 55: ...SECTION 6 ELECTRICAL SCHEMATICS 55 Wiring Diagram E380 V 36kW PS360EW CE 78142 REV B Sheet 1 of 2...
Страница 56: ...SECTION 6 ELECTRICAL SCHEMATICS 56 Wiring Diagram E380 V 36kW PS360EW CE 78142 REV B Sheet 2 of 2...
Страница 57: ...SECTION 6 ELECTRICAL SCHEMATICS 57 Wiring Diagram E380 V 36kW PS360EW Non CE 78143 REV B Sheet 1 of 2...
Страница 58: ...SECTION 6 ELECTRICAL SCHEMATICS 58 Wiring Diagram E380 V 36kW PS360EW Non CE 78143 REV B Sheet 2 of 2...
Страница 59: ...SECTION 6 ELECTRICAL SCHEMATICS 59...