TECHNICAL SPECIFICATIONS

Dimensions

Weight

Battery

Operating Temperature

Operating Relative

Humidity

2U Rack: 17.05 In. x 3.5 In. x 18.9 In.

                (43.3 cm x 8.8 cm x 48 cm)

70.5 Lb. (32 kg.)
Sealed maintenance free lead acid

battery (12V/9.0 AH x 8)

32  F to 104  F (0  C to 40  C)

o

o

o

o

0 to 95% non-condensing

FCC NOTICE

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and (2) this device must accept any interference that 

may cause undesired operation.

WARNING!!   This equipment has been tested and found to comply with the limits for a Class A digital

device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection

against harmful interference when the equipment is operated in a commercial environment. This 

equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in

accordance with the instruction manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause harmful interference in which case the

user will be required to correct the interference at his own expense.

PRODUCT CHARACTERISTICS

VALUE/MEASUREMENT

NOTE:  The battery pack should be located directly below the UPS in the rack in order to connect the 

            48 VDC output cable to the UPS as shown in Figure A. If installing the battery pack and the UPS 

            is located in the bottom of the rack, the UPS should be moved before installing the expansion 

            battery pack.

INSTALLATION AND MOUNTING
1) If using the provided handles install them now 

    using provided 8-32 screws. (FIGURE A)

    

    NOTE: The handles cannot be installed

                after the unit is rack-mounted. 

FIGURE A

RACK EAR

RACK EAR

 SCREW (6X)

2) Install ears as shown using provided 10-32 screws. 

    Six screws per ear, one ear per side.

Содержание UPS-EBPR

Страница 1: ...ughly before removing the expansion battery pack from the shipping carton and before installing and making any connections to or from the battery pack PRODUCT FEATURES Extends runtime of UPS Additiona...

Страница 2: ...product The lightning flash with the arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that...

Страница 3: ...Page 3 TABLE OF CONTENTS Page No Important safety Instructions Unpacking 2 Features 4 Technical Specifications 5 FCC Notice 5 Installation and Mounting 5 6 Connection to UPS 7 Warranty 8 2...

Страница 4: ...ltiple battery packs TM Circuit Breaker Switch Switches battery pack on or off The circuit breaker switch must be in the OFF position when either making a connection to or disconnecting from either th...

Страница 5: ...onment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicatio...

Страница 6: ...t onto the other Rear Mounting Bracket Once the ears and the Rear Mounting Brackets are fully engaged slide to unit to the back of the enclosure 4 Install the front of the unit to the rackrail FIGURE...

Страница 7: ...ors are color coded red black green Ensure connectors are secured to each other per matching color red to red black to black green to green CIRCUIT BREAKER SWITCH RESET AC Output AC Input charge only...

Страница 8: ...maintenance THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PU...

Отзывы: