background image

 

 
 

Manual Number 9019161 

Revision A, September 9, 2020 

12 

 

 

 

 

Figure 3.2 Mating Cable Harness Assembly 

 

 

Cable Harness Kit Parts 

Item  Qty  Description 

1  DSub, 26pin HD, with #22 contacts  

1  Backshell 

2  Backshell blanking plate 

1  Spring Clip 

1  Slide Lock 

2  Screw, Pan-head Phillips 

2  Cable Clamp 

2  Screw, Flat-head Phillips, Long 

1  Backshell Cover 

10 

4  Screw, Flat-head Phillips, Short 

10 

shields 

Содержание MD23 Series

Страница 1: ...Manual Number 9019161 Revision A September 9 2020...

Страница 2: ...630 0101 Fax 316 630 0723 ks customerservice mcico com www mcico com We welcome your comments concerning this manual Although every effort has been made to keep it free of errors some may occur When r...

Страница 3: ...Manual Number 9019161 Revision A September 9 2020 3 REVISION HISTORY Rev Date Detail Approved A 09 09 2020 Production release BAW...

Страница 4: ...F CABLES 7 LIMITATIONS 7 MODIFICATION 8 SECTION 3 INSTALLATION PROCEDURES 9 GENERAL INFORMATION 9 PARTS LIST 9 CABLE HARNESS 9 PNEUMATIC PRESSURE CONNECTIONS 13 MOUNTING 13 INSTALLATION COMPLETION 14...

Страница 5: ...ic inputs A USB port is accessible behind a cover on the rear of the unit for field loadable software updates and installation of a Custom Instrument Definition CID file The unique Multi I O MIO featu...

Страница 6: ...al or single point to ground ARINC 429 input output Low High Speed input 2 pair High Speed output 1 pair RS 232 Protocol per RS 232 specification data format per CID 1 pair Thermocouple Type K 1 pair...

Страница 7: ...may be susceptible to high energy flow Avoid sharp bends in cabling and routing near aircraft control cables Also avoid proximity and contact with aircraft structures avionics equipment or other obst...

Страница 8: ...rtification s and technical specifications of the unit It also includes the MOD or modification number representing notable changes in the hardware design of the unit Modification MOD 0 is the initial...

Страница 9: ...atic Connector quick disconnect 2 pneumatic connector kit only included with the pitot static version CABLE HARNESS Construct the cable harness in accordance with the instructions below including the...

Страница 10: ...e separate pairs on pins 23 15 24 25 and 17 26 Also described below as MIO 7 8 9 10 and 11 12 The functions of these pins are detailed further in Section 4 Connector Pinout Pin Description Pin Descrip...

Страница 11: ...ckshell Spring Clip Item 4 into the thin slot of the backshell as shown 6 Place the Backshell Slide Lock Item 5 over the D Sub connector 7 Install the D Sub connector with Slide Lock and cable harness...

Страница 12: ...ss Kit Parts Item Qty Description 1 1 DSub 26pin HD with 22 contacts 2 1 Backshell 3 2 Backshell blanking plate 4 1 Spring Clip 5 1 Slide Lock 6 2 Screw Pan head Phillips 7 2 Cable Clamp 8 2 Screw Fla...

Страница 13: ...nap lock into place once they are fully engaged MOUNTING The MD23 FLEXis designed primarily to be rear mounted in an aircraft instrument panel Refer to Section 2 2 for Equipment Location information T...

Страница 14: ...eak check of the pitot static system per the aircraft maintenance manual or industry practice Verify the proper CID number is installed for the application Table 3 3 MD23 Unit Versions Figure 3 3 MD23...

Страница 15: ...Manual Number 9019161 Revision A September 9 2020 15 Figure 3 4 Panel Cutout...

Страница 16: ...Type A data port on the rear of the unit Each unique CID file is assigned an identification number and revision typically in the format of 1 X where is a three digit number and X is the revision star...

Страница 17: ...ush and turn The knob provides 16 detents per revolution and typically increments whatever element it is controlling on the display one unit per detent It can also be used to scroll between controllab...

Страница 18: ...ht After confirming any setting by selecting it that setting will become immediately active and be saved in memory regardless of whether the EXIT command is selected or it times out and automatically...

Страница 19: ...While in Flight Mode the Options Menu can be accessed at any time with a press and hold of the Control Knob for approximately three 3 seconds The Options Menu offers selections that are available duri...

Страница 20: ...Brightness Adjustment After selecting the Brightness menu option the Brightness adjust bar will appear Turning the Control Knob will adjust offset the display brightness green bar above or below the c...

Страница 21: ...tware version and CID version Pressing the Control Knob will revert to the active display Figure 4 5 Figure 4 5 Info Menu 4 4 1 4 EXIT The Exit action allows the user to manually close the Options Men...

Страница 22: ...rs and trained personnel should access the Configuration Mode during initial installation or during maintenance adjustments and updates Enter the Configuration Mode by pressing and holding the Control...

Страница 23: ...t INTERNAL option which senses the ambient light conditions and adjusts the display brightness dimming automatically If an external source is to be used the EXT 5V EXT 14V and EXT 28V options represen...

Страница 24: ...er is selected in Dimming Control Blue vertical line represent the current Dimming Control input value Y axis represents brightness of the display Blue horizontal line represent the current display br...

Страница 25: ...crease the brightness of the display to the desired level at that lighting condition the point will move up or down respectively The numeric value of the dimming point is displayed in green left of th...

Страница 26: ...e file is not found or the update file already matches the loaded data an error message will appear Acknowledgement by pressing the Control Knob will revert to the Configuration Menu If a valid update...

Страница 27: ...e if the specific design of the CID includes it and gray unavailable otherwise See the applicable User Guide associated with the loaded CID for specific details Figure 4 11 Figure 4 11 User Configurat...

Страница 28: ...lay can be cleaned using a lint free cloth moistened with water No chemicals should be used to clean the display If the unit fails to perform to specifications the unit must be removed and serviced by...

Страница 29: ...Configuration Mode by press and holding the Control Knob on the faceplate while applying external power to the unit 3 Turn the Control Knob to highlight the UPDATE option 4 Press the Control Knob to i...

Страница 30: ...ry W Fluids 11 Category X Sand and Dust 12 Category X Fungus 13 Category F Salt Fog 14 Category X Magnetic Effect 15 Category Z Power Input 16 Category Z XX Voltage Spike 17 Category A Audio Frequency...

Отзывы: