![Midcontinent MD23-104 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/midcontinent/md23-104/md23-104_user-manual_1790194005.webp)
MD23-104
User Guide
Mid-Continent Instruments and Avionics
5
User Guide UG104, Revision 1
January 4, 2022
(page 1 – one battery)
(page 2 – one battery)
(page 1 – two batteries)
(page 2 – two batteries)
Individual elements are defined as follows:
Page 1
o
Status:
Displays battery status: Active, Fault, Service, Invalid, or No Start
o
Charge %: Displays current state of charge. 0-100%
Number is amber if state of charge is below battery-programmed minimum
Battery Icon represents state of charge and depletes in relation to charge %
Icon is amber if state of charge is below battery-programmed minimum
Icon contains green lightning bolt when battery is charging
o
Volts:
Current voltage of the battery
Number turns amber when under-voltage or over-voltage
o
Amps:
Discharge or charge current (discharge current denoted as negative (-))
o
Temp:
Internal temperature of the battery, in degrees Celsius
Number is red if temperature exceeds the upper limit of the battery
Heater Icon represents the current state of the battery heater
Icon is a gray horizontal bar if heater is inactive/offline
Icon is a gray bar with squiggles if heater is active/available
Icon is a white bar with squiggles if heater is current on/heating
Page 2
o
Life:
Remaining percentage between original max and battery-programmed
end of life capacity. 0-100%
o
Capacity:
Current maximum capacity of the battery. Number is amber if capacity
is below the battery-programmed end of life capacity.
o
Faults:
Reported battery faults. “(None)”, if none.