MIDAS TOUCH INC
40
MAC-1000PEF/PMF Hardware Manual
4.2.2.6 Door Sensor Detection Time
Application only if door sensor is installed. Default value is 0 which means this function is
deactivated. Sensor detection time may be set from 1~255 seconds. (If parameter value is
greater than 255 seconds, the parameter is ineffective).
When door sensor detection time has been set, system will monitor door’s status. If the
allotted door open time has expired and door does not close, controller will make beep
sound continuity until the door has to be closed. However, if door was forced open,
controller will activate the alarm relay to alert the administrator or security personnel. To
deactivate the alarm relay, input the disarm code. (Default is 0000)
Operation Instruction:
Master Card/Code
(Default 30191000)
Access Info
Default is 0 second
which signifies
deactivates function.
Door Sensor
NEW =
Completed