20
10
0
-10
-20
-30
20
200
2K
20K
20K
20
10
0
-10
-20
-30
20
200
2K
20
10
0
-10
-20
-30
20
200
2K
20K
•
E151
•
E153
•
E152
Directional characteristic
SPECIFICATIONS
AUDIO CONNECTION
To connect the microphone to your equipment, use a balanced XLR
microphone cable with the following pin assignment: Pin 1 = shielding, pin 2
= +, pin 3 = -. Since all the microphone contact points are gold-plated, your
microphone cable should also have gold-plated connectors, if possible.
MICROPHONE INSTALLATION
If the microphone is not stable, you
could cross the elastic band to hold it
firm. .
First attach the microphone
capsule then screw a clamp onto
the stand.
Polar pattern
Capsule diameter
Sensitivity (±3dB)
Frequency Response
Power Supply
Total harmonic distortion (THD)
Thermal Noise
Output impedance
Length
weight
Connector
Cardioid | Super-cardioid | Omni
20 mm
-42 dB re. 1v/Pa
20 Hz ~ 20kHz
48 V Phantom power
< 1% up to 135 dB SPL peak
< 17 dBA
< 100 Ohm
155mm
185g
3-pin XLR
Capusle
E151
|
E152
|
E153
0 Deg
180 Deg
0 Deg
180 Deg
0 Deg
180 Deg