1 4
5.
TESTING
5.1
Inspect heat pump before use
a)
The ventilating device and outlets are operating adequately and are not obstructed.
b)
It’s prohibited to install refrigeration pipe or components in corrosive environment.
c)
Inspect the electric wiring on basis of the electric wiring diagram and earthing connection.
d)
Double confirm the main machine power switch should be off.
e)
Inspect the air inlet and outlet.
5.2
Trial
a)
The user must “Start the Pump before the Machine, and Turn off the Machine before the
Pump”, or the machine will be damaged.
b)
Before start the heat pump, please check for any leakage of water.
c)
In order to protect the swimming pool heat pump, the machine is equipped with a time lag
starting function, the fan will run 1 minute earlier than the compressor when starting the
machine, and it will stop running 1 minute later than the compressor when power off the
machine.
d)
After the swimming pool heat pump start up, please kindly checking for any abnormal noise
from the machine.
6.
MAINTENANCE
6.1
In winter season when you don’t swim:
•
Cut off power supply to prevent any machine damage.
•
Drain water clear of the machine.
•
Cover the machine body when not in use.
Important:
Unscrew the water nozzle of inlet
pipe to let the water flow out.
When the water in machine freezes in
winter season, the titanium heat exchanger
may be damaged.
“
CUT OFF
”
power supply of the heater before
cleaning, examination and repairing