MICROWELL HP COMMERCIAL iMAX110 Скачать руководство пользователя страница 1

– 

Version: 04/2020 

(last update: 2020-

0

4-

2

4)

 

HEAT 

PUMP 

for swimming pool water 

heating & cooling 

HP COMMERCIAL Inverter iMAX60 

HP COMMERCIAL Inverter iMAX110 

Installation and user manual

 

Содержание HP COMMERCIAL iMAX110

Страница 1: ... Version 04 2020 last update 2020 04 24 HEAT PUMP for swimming pool water heating cooling HP COMMERCIAL Inverter iMAX60 HP COMMERCIAL Inverter iMAX110 Installation and user manual ...

Страница 2: ...ocal regulations in your country regarding installation and usage of this heat pump which are valid in addition to this User manual We hope you ll enjoy using our heat pumps Contents 1 Safety Precautions 4 1 1 Warning 4 1 2 Attention 4 1 3 Safety 4 2 About your heat pump 4 2 1 Transportation 4 2 2 Accessories 5 2 3 Operating condition and range 5 2 4 Introduction of different modes 5 2 5 Technical...

Страница 3: ...0 iMAX110 I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 3 V e r s i o n 0 4 2 0 2 0 7 1 Failure solution and code 15 8 Electrical wiring schematic optional 17 9 Wi Fi operation 19 H E A T P U M P M I C R O W E L L H P ...

Страница 4: ...cy of the heater will be reduced or even stopped c Don t use or stock combustible gas or liquid such as thinners paint and fuel to avoid fire d In order to optimize the heating effect please install heat preservation insulation on pipes between swimming pool and the heater and please use a recommended cover on the swimming pool e Connecting pipes of the swimming pool and the heater should be 10m 1...

Страница 5: ...ating condition and range To provide you comfort and pleasure please set swimming pool water temperature efficiently and economically The heat pump can work between air 10 C 43 C and its ideal operation range is between air 15 C 25 C 2 4 Introduction of different modes a The heat pump has two modes Boost and Silence b They have different strengths under different conditions Mode Modes Strength Boo...

Страница 6: ...wer kW 2 26 8 90 4 68 17 5 Rated input current A 3 27 12 9 6 78 25 3 Sound level at 10m dB A 33 0 41 0 35 0 44 0 Advised water flux m h 20 25 40 50 Water connection mm 75 110 Net dimension LxWxH mm 1000x1110x1260 2100x1090x1280 Net Weight kg 212 459 Remarks This heat pump is able to perform normal within air temp 10 43 efficiency will not be guaranteed out of this range Please take into considerat...

Страница 7: ...u a l P a g e 7 V e r s i o n 0 4 2 0 2 0 2 6 Dimensions B F G E H A C E B F G D A H C A B C D E F G H iMAX60 1000 660 1110 1070 1000 780 105 1260 A B C D E F G H iMAX110 1000 1630 1090 1050 2100 515 140 1280 Name Size mm Model Name Size mm Model H E A T P U M P M I C R O W E L L H P ...

Страница 8: ...cket must be strong enough and antirust treated 2 Please don t stack substances that will block air flow near inlet or outlet area and there is no barrier within 50cm behind the main machine or the efficiency of the heater will be reduced or even stopped 3 The machine needs an appended pump Supplied by the user The recommended pump specification flux refer to Technical Parameter Max lift 10m 4 Whe...

Страница 9: ...n d u s e r m a n u a l P a g e 9 V e r s i o n 0 4 2 0 2 0 1 How to connect to the terminal board of iMAX60 Step 1 open the maintenance panel Remove three screws outside Open the panel Remove two screws inside Open the internal H E A T P U M P M I C R O W E L L H P ...

Страница 10: ...X110 V e r s i o n 0 4 2 0 2 0 P a g e 1 0 Step 2 Power cord must be passed through below 3 holes Connect the wire through three holes Restore the internal panel Fix the internal panel by two screws Restore the panel Fix the panel by three screws H E A T P U M P M I C R O W E L L H P ...

Страница 11: ... Electric wiring Diagram For power supply 400V 50Hz Note 1 Must be hard wired plug is not allowed 2 The swimming pool heat pump must be earthed well 3 4 References for protecting devices and cable specification Above data is subject to modification without notice Note The above data is adapted to power cord 10m If power cord is 10m wire diameter must be increased The signal cable can be extended t...

Страница 12: ...g mode 18 40 C iii Cooling mode 12 30 C iv Auto mode 12 40 C i Boost ii Silence Temperature Setting Attention i The controller has power down memory function ii The buttons will turn dark when it s locked 4 2 Operation Instruction a Screen Lock 1 Press for 3 seconds to lock or unlock the screen 2 Automatic Lock Period 30 seconds if no operation b Power On Press for 3 seconds to unlock screen Press...

Страница 13: ...n Press to switch among boost mode silence mode Default mode boost Please choose boost mode for initial heating e WIFI When the screen is on press for 3 seconds after flashing enter Wi Fi connection Connect Wi Fi on mobile phone and input password and then control equipment by Wi Fi When APP connects Wi Fi successfully lights on f Defrosting 1 Automatic defrosting When machine is auto defrosting w...

Страница 14: ... pump please check for any leakage of water c In order to protect the swimming pool heat pump the machine is equipped with a time lag starting function the fan will run 1 minute earlier than the compressor when starting the machine and it will stop running 1 minute later than the compressor when power off the machine d After the swimming pool heat pump start up please kindly checking for any abnor...

Страница 15: ...blocked Remove the obstacles 3 minutes start delay Wait patiently Display normal but no heating Set temp too low Set proper heating temp 3 minutes start delay Wait patiently If above solutions don t work please contact your installer with detailed information and your model number Don t try to repair it yourself Note If the following conditions happen please stop the machine immediately and cut of...

Страница 16: ...Cooling coil pipe temp sensor failure 15 P7 Ambient temp sensor failure 16 P8 Cooling plate sensor failure 17 P9 Current sensor failure 18 PA Restart memory failure 19 F1 Compressor drive module failure 20 F2 PFC module failure 21 F3 Compressor start failure 22 F4 Compressor running failure 23 F5 Inverter board over current protection 24 F6 Inverter board overheat protection 25 F7 Current protecti...

Страница 17: ... s i o n 0 4 2 0 2 0 8 Electrical wiring schematic optional Breaker fuse Customer prepare Earthing Power Supply 400V 50Hz Water pump 400V voltage Water Pump Water Pump Breaker fuse Customer prepare Power Supply 400V 50Hz Earthing Power Cord Contactor coil voltage 400V H E A T P U M P M I C R O W E L L H P ...

Страница 18: ...g e 1 8 Water pump control and timer connection 1 Water pump timer 2 Water pump wiring of Heat Pump Note The installer should connect 1 parallel with 2 as above picture To start the water pump condition 1 or 2 is connected To stop the water pump both 1 and 2 should be disconnected H E A T P U M P M I C R O W E L L H P ...

Страница 19: ...il iPhone please download from 2 Create your password APP Binding Please make sure you are connected to the Wi Fi Press for 3 seconds to unlock the screen press for 3 seconds then release after hearing Beep Enter Wi Fi code During connection flashes When the APP connects to the Wi Fi successfully the will display APP Download Android please download from H E A T P U M P M I C R O W E L L H P ...

Страница 20: ... l a t i o n a n d u s e r m a n u a l HP COMMERCIAL Inverter iMAX60 iMAX110 V e r s i o n 0 4 2 0 2 0 P a g e 2 0 Click Add device and then follow instructions to pair device H E A T P U M P M I C R O W E L L H P ...

Страница 21: ...HP COMMERCIAL Inverter iMAX60 iMAX110 I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 2 1 V e r s i o n 0 4 2 0 2 0 H E A T P U M P M I C R O W E L L H P ...

Страница 22: ...tion The Current swimming pool water temperature Timer For heat pump with Heating Cooling function Indicate the Max Silent mode Select Heating Cooling The setting temperature Select Max Silent Notice 1 The weather forecast is just for reference 2 APP is subject to updating without notice On Off H E A T P U M P M I C R O W E L L H P ...

Страница 23: ...HP COMMERCIAL Inverter iMAX60 iMAX110 I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 2 3 V e r s i o n 0 4 2 0 2 0 Notes H E A T P U M P M I C R O W E L L H P ...

Страница 24: ...AX60 iMAX110 V e r s i o n 0 4 2 0 2 0 P a g e 2 4 Distributed by Manufacturer MICROWELL spol s r o SNP 2018 42 927 01 Sala Slovakia tel 421 31 770 70 82 e mail microwell microwell sk w w w m i c r o w e l l e u M a d e i n S l o v a k i a H E A T P U M P M I C R O W E L L H P ...

Отзывы: