swimming pool. The water may be contaminated with bacteria.
•
Children are not allowed to operate, touch or play with the unit.
•
Children are not allowed to manipulate with packaging, plastic / bubble foil. Risk of suffocation!
•
Prevent the children from injury or harm caused by any manipulation with the unit, its parts or its
packaging. Small parts like screws may be swallowed and cause harm to health.
•
Do not leave the children in the swimming pool / at the swimming pool unattended.
•
The positioning of the heat pump must be in accordance with the STN 33 2000-7-702 standard, i.e.
it must be placed at least 3,5 m from the swimming pool´s external border.
•
For heating/cooling the swimming pool by the heat pump, the filtration pump must run and the
water must flow through the heat exchanger.
•
Never turn on the heat pump if it is without water and if the filtration device is not operating.
•
Protect the heat pump from freezing. Eliminate the water from the filtration and from the heat
pump’s water heat exchanger and prepare the product for the winter time.
•
At low surrounding ambient temperature level (below 10°C) and high relative air humidity level (e.g.
after rain, during the night, etc.), the evaporator may get iced up. Heat pump will automatically
defreeze itself. Its operations or functionality is not harmed but the efficiency decreases.
•
Manufacturer does not bear any responsibility concerning damages caused by inappropriate heat
pump performance and/or model selection, installation or application. Heat pump is considered
undersized in the case it works usually and in long-term more than 18 hours daily. General warranty
void applies for damages on the device or other damages if the device works usually in long-term
more than 18 hours daily.
•
The heat pump must be correctly sized for its application.
•
Do not pressurize the water heat exchanger higher than 0.15MPa (1.5bar). By pressure of 0.2MPa
(2bar) the water heat exchanger gets irreversibly damaged. It is advised to install a security valve
with pressure threshold at 0.15MPa (1.5Bar) before the heat exchanger.
•
Do not apply or use water of higher temperature than 40°C in water heat exchanger. Water
temperature above 45°C irreversibly damages the water heat exchanger.
2.3
Handling precautions
•
Leave the unit in vertical upright position for at least 2 hours before the installation.
•
Transport in lying position or turning the device over may harm the compressor resulting in unit’s
malfunction, failure or damage and will lead to loss of warranty.
•
The device must be handled with care and special attention avoiding any mechanical damage.
•
It is forbidden to apply any improper mechanical force onto the unit. This may cause mechanical
damage to the device.
•
It is forbidden to let the device fall freely onto the ground or any solid surface resulting in hard
impact.
•
Please notify your reseller or distributor if you suspect that the unit was delivered damaged. Unit
may seem to work well at start but small damage can make the unit go out-of-order in short time.
In such case the unit must be inspected and approved for further use by your reseller.
•
Please notify your reseller or distributor if directly after installation you suspect that unit is not
working in perfect order.
•
In the case of device failure resulting from improper handling or mechanical damage (impact, hit,
fall, etc.), the manufacturer reserves the right to evaluate the continuity of warranty.