WARNINGS 

 

NEVER WORK ON THE SYSTEM WITH THE ELECTRICAL POWER ON. 

 

NEVER ALLOW PERSONS OR ANIMALS TO STAND ON THE GATE OR 
TRACK WHILE THE GATE IS IN MOTION. 

 

KEEP HANDS CLEAR OF THE RACK  AND PINION GEAR WHILE THE 
MOTOR IS IN OPERATION. 

 

DO NOT ALLOW ANYONE TO PUT THEIR HAND THROUGH THE GATE 
TRELLIS WHILE GATE IS MOVING.  

 

TEST ALL OPERATING SYSTEMS ON A REGULAR BASIS, 
ESPECIALLY THOSE RELATED TO THE SAFETY FEATURES. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание GEMINI 220 V

Страница 1: ...Page 1 NOTES...

Страница 2: ...ing the Remote Control Security Code Dip Switches 10 Programming a GEMINI Remote Control 10 Fitting the Alluminium Stoppers 12 Reversing the Electrical Motor Direction 12 Obstruction Sensing Adjustmen...

Страница 3: ...n turn is cemented or bolted to a concrete base The complete unit is enclosed with a weather resistant lid The GEMINI system is rigidly build for reliability but with safety as first priority The elec...

Страница 4: ...ditional reliability Obstruction Mechanical adjustable obstruction sensing in both directions Can accommodate I R beam sensors Activation By using any N O electrical circuit push button or remote cont...

Страница 5: ...ide lever and padlock lug 5 220 Volt electrical motor 6 Gearbox 7 GEMINI electronic control card 8 MAINS connector block 9 Gate obstruction impact switch 9a Gate obstruction sensing adjustment 10 Gate...

Страница 6: ...AND ON THE GATE OR TRACK WHILE THE GATE IS IN MOTION KEEP HANDS CLEAR OF THE RACK AND PINION GEAR WHILE THE MOTOR IS IN OPERATION DO NOT ALLOW ANYONE TO PUT THEIR HAND THROUGH THE GATE TRELLIS WHILE G...

Страница 7: ...el with the centerline of the pinion This will ensure that the centerline of the rack will run on the centerline of the pinion Clearly mark the position of the base plate Remove the complete unit and...

Страница 8: ...1 mm between the pinion and the rack When moving the gate to the next position the manual override lever must be lowered For wooden gates drill two holes in the angle iron bracket and secure to the ga...

Страница 9: ...red directly from a power source As a safety precaution an ON OFF switch must be incorporated into the electrical circuit normally within 1 meter from the unit Electrical power supply Connect to the t...

Страница 10: ...tronic control card as illustrated CAUTION Ensure that all the legal requirements for your local area are complied with SETTING THE REMOTE CONTROL SECURITY CODE DIP SWITCHES Once the electrical supply...

Страница 11: ...o the same on the receiver From dip switch No 2 to No 12 place the switches in random sequence to the ON or OFF positions Ensure that the receiver dip switch settings match the transmitter settings Yo...

Страница 12: ...b screws using an Allen key REVERSING THE ELECTRICAL MOTOR DIRECTION Refer to the electrical diagram on Page 22 The electrical motor direction default is set by positioning the gate direction jumper o...

Страница 13: ...tially activated during installation and the gate direction is incorrect the gate direction jumper must be unplugged and moved to the opposite set of pins Ensure that the jumper is fully plugged in OB...

Страница 14: ...reases the spring 3 tension thus causing the impact sensing to be more sensitive Test impact sensitivity by bumping the gate by hand in the opposite direction of movement Adjust the tension of both sp...

Страница 15: ...e a time delay to suit your personal requirements i e 50 seconds dip switch settings must be 1010 Move the No 1 dip switch to the ON position the second switch to the OFF position the third switch to...

Страница 16: ...r the time as pre selected during the Auto Close dip switch settings Gate will move to the fully closed position and stop If necessary adjust the alluminium stopper position on the rack 4 Perform an o...

Страница 17: ...e gate senses an obstruction while opening the gate will stop and wait for the next command If the Auto Close function is selected the gate will close after the preset time LED DISPLAY 6 The external...

Страница 18: ...SWITCHED ON LIVE THEREFORE UTMOST CARE MUST BE TAKEN TO PREVENT ELECTRICAL SHOCKS TABLE 1 PROBLEMS DURING THE INSTALLATION OPERATING PHASE PROBLEM POSSIBLE CAUSE REMEDY AND OR TEST Electrical motor d...

Страница 19: ...tions at the connector block If motor operates the wiring is faulty and must be repaired b Push button faulty b Disconnect push button wiring at the push button Momentarily bridge the wires at the pus...

Страница 20: ...s and closes by itself a Faulty push button wiring a Check and rectify as necessary b Faulty remote control receiver b Replace the remote control receiver c Somebody in your area is using the same sec...

Страница 21: ...tion lid and blow off all accumulated dust and dirt from the unit with low pressure compressed air REPLACING THE REMOTE CONTROL BATTERY Using a small Phillips screwdriver remove the rear cover from th...

Страница 22: ...Page 22 ELECTRICAL DIAGRAM...