background image

 

3

Rear View OF ScanMaker 3880 

 

 

 

 

 

 

 

Accessory of SM 3880 : LightLid-35 ( P/N :1108-03-520041 ) 

                       

 

 

If your SM 3880 equips with LightLid 35 for film scanning, then we suggest you to do 

Lightlid 35   

calibrator

 before you start ScanWizard to scan slide / negative film with Lightlid 35 for better quality.   

 

 

USB 2.0 interface 

connector *1 

 

Power jack of scanner 

( 12Vdc / 1.25A ) 

Power Label 

( P/N : 219-21-820000 )

 

15 pin connector 
for LightLid 35 

The Label of scanner S/N. 

Attention Tag for power use 

LightLid 35 

Calibrator is an 

AP

 and support 

to do lamp 

calibration for 

your LightLid 35. 
Left illustration is 

a windows 

message after 

you start 

LightLid 35 

calibrator. You 
can click 

“ calibrate “ to 

do lamp 

calibration after 

lamp in Lightlid 

35 is warmed up 
for 3 minutes.   

Содержание ScanMaker 3880

Страница 1: ...r 3880 14 FEATURE LIST OF ScanMaker 3880 16 THE LOGO OF SAFETY MARK AND EMI FROM POWER LABEL OF ScanMaker 3880 17 SYSTEM WIRING DIAGRAM OF ScanMaker 3880 18 SYSTEM BLOCK DIAGRAM OF ScanMaker 3880 19 W...

Страница 2: ...8 5 W A D CONVERTER Chip Scan113 16BIT Pixel on Main Board MARCH 0503 SENSOR HOME SENSOR 1 IN THE BUTTON BOARD MARCH BUT STEPPING MOTOR 12Vdc 0 5A NEOCENE 2T3542142 MOTOR STEP 3 75 DEGREE STEP MICRO S...

Страница 3: ...or better quality USB 2 0 interface connector 1 Power jack of scanner 12Vdc 1 25A Power Label P N 219 21 820000 15 pin connector for LightLid 35 The Label of scanner S N Attention Tag for power use Li...

Страница 4: ...omplete to install scanner driver ScanWizard 5 into PC Windows system and then you can find the icon of Microtek Scanner Configuration ScanWizard 5 and My Image will list you on the Desktop of Windows...

Страница 5: ...ype DSA 0151A 12 UP EU AP 220VAC P N 545 00 520016 UK type HDAD15W101 126 UK 240VAC P N 545 00 580003 Australia type DSA 0151A 12 AS AUS 220VAC P N 545 00 520018 The function of AC Inverter Board is t...

Страница 6: ...c5 IDLE PULLEY ASSEMBLY P N I41 009984 c6 SLIDING ROD P N 215 31 520000 c7 TIMING BELT 388mm P N 404 88 000388 c8 CCD Flexible Flat Cable 19 pin 404mm P N 121 80 820000 c9 Button Flexible Flat Cable...

Страница 7: ...embly I41 013142 Book Cover Assembly 215 01 820002 Upper Housing Assembly I41 013142 Base Assembly I41 013143 This center mark is for scanner CCD center alignment during calibration The white area in...

Страница 8: ...Button Flexible Cable 121 80 820001 Button Board 1108 01 820002 Sensor Bar Timing Belt 404 88 000388 Sliding Rod 215 31 520000 Motor Assembly 215 17 820000 Cold Cathode Lamp 570 19 520000 Idle Pulley...

Страница 9: ...iming Belt 388MXL 404 88 000388 LOCK Mechanism of ScanMaker 3880 Cold Cathode Lamp 570 19 520000 CCD Assembly I41 013145 Lens Cover 215 00 520002 Carriage Roller 215 00 520003 AC Inverter Board 545 00...

Страница 10: ...Cable 19 pin 435mm 121 80 820001 Insulation Filmfor main board 215 00 520008 I USB2 0 Gray Cable 121 44 150504 Button Flexible Flat Cable 9 Pin 404mm 121 80 820000 Core M5W ZP33 5 6 5 12 141 10 52000...

Страница 11: ...44 520012 Support Frame 215 00 222000 Plastic Handle 580 01 222000 Power Adapter 12Vdc 1 25A Carton for SM 3880 219 31 820000 S W BUNDLE P N I41 013151 AP VERSION S W BUNDLE P N I41 013150 EU VERSION...

Страница 12: ...each of line sensor has 5 400 pixels totally but the effective pixels of each CCD line sensor for SM 3880 is 5 100 pixels only Hence R1 R2 10 200 pixels The scan area of SM 3880 is 8 5 W 11 7 L This...

Страница 13: ...scanner by using one cross head screwdriver Step 2 Separate the upper housing assembly from rear end of scanner by both hands and show you as below illustration Step 3 Separate the upper housing assem...

Страница 14: ...Lock NG 4 Power Adapter NG 1 Button Board NG 2 9 Pin button cable NG 3 Base Lock NG 4 Timing Belt NG 1 Main Board NG 2 Wrong scanner driver 3 USB Cable NG 4 Carriage Assembly NG 5 19 Pin CCD flat cab...

Страница 15: ...PC Windows system LED light up in Green steadily Color image NG on photo scanning OK Fail Fail Fail Button Function NG This is an icon of Scanner Finder it means scanner has linked with PC Windows sys...

Страница 16: ...ORY None it is driven by S W ScanWizard 5 directly USB1200 Scanner in S W Driver SM 3830 SM 3640 SM 3740 SM 3840 USB2400 Scanner in S W Driver SM 4850 SM 4900 USB2 0 Scanner in S W Driver SM 5800 SM 5...

Страница 17: ...out it get the logo of Safety Mark and EMI as follows FCC is the logo of EMI from US Energy Star is the logo from Energy Saving Association of US ETL is the logo of Safety Mark from US and Canada VCC...

Страница 18: ...18 SYSTEM WIRING DIAGRAM OF ScanMaker 3880...

Страница 19: ...19 SYSTEM BLOCK DIAGRAM OF ScanMaker 3880...

Страница 20: ...3 In SW 5 or in Microtek Scanner Finder it will tell you the model code of SM 3880 is 1200dpi Scanner after SM 3880 link with PC via USB2 0 cable under PC Windows system In Scanner Information it will...