Maintenance
After usage for a period of time, the rollers may become worn out, and problems such as
document double-feed may occur. In this case, check rollers and replace them with new ones
if needed.
First of all, open the scanner cover, as detailed in the “Fixing the Paper Jams” section in this
guide. When the scanner cover is opened, locate the rollers as you want to change.
Replacing Separation Roller
Locate the Separation Roller Assembly and then pull down the cover of the roller with your
finger. Take out the roller and replace it with the new one.
NOTE
:
•
The recommended replacement point for the Separation Roller is approximate after 150,000 scans; for
Feed Roller Assembly is around 100,000 scans.
•
Please contact your local resellers for purchasing new rollers.
•
For more details of replacement, refer to the scanner’s User’s Manual in the Microtek Software CD/DVD
and see the “Maintenance” section on pages 48 to 52.
Replacing the Feed Rollers
Locate the Feed Roller Assembly and then pull down the cover of the rollers with your finger.
Take out the rollers and replace them with the new ones.