background image

ArtixScan 1800f Installation and Operation Manual     21

Performing Color Calibration

The Microtek Scanner ICC Profiler (MSP) is a scanner calibration and profiling utility
program exclusively designed for Microtek scanners. Used together with the color
calibration target, the ICC Profiler determines the color attributes of your scanner
accurately, then generates an ICC profile tailored exclusively for the scanner you are
using under ScanWizard Pro.

The Microtek Scanner ICC Profiler utility is included in the CD-ROM that contains
ScanWizard Pro. Select the Microtek Scanner ICC Profiler option to install.

The color calibration target

Two industry-standard Kodak color targets – Reflective (Kodak Q-60R1, size 5" x 7")
and Transparency (Kodak Q-60E1, size 4" x 5") — for calibration are included in the
scanner accessories package.

The calibration target is very delicate and must be handled carefully, as follows:

Gently remove the target from its protective sleeve and avoid touching the target
image surface.

When not in use, keep the target in its sleeve and away from light and heat.

Note: To keep the colors in your scanner consistent, you should perform color
calibration on a regular basis. Professional photographers, graphic designers or
others who require extremely precise color may wish to calibrate the scanner every
time it is used.

Positioning the Target on Scanner

Before calibration, make sure that the Scanner ICC Profiler program is successfully
installed, and that the calibration target is placed on your scanner correctly.

Proper positioning of the target (either reflective or transparent target) on the scanner
is important for successful calibration. Incorrect positioning of the target will result in
an unsuccessful calibration.

Содержание ArtixScan 1800f

Страница 1: ...Microtek ArtixScan 1800f Installation and Operation Manual...

Страница 2: ...s of the copyright holder Microtek bears no responsi bility for the unauthorized use of copyrighted materials To obtain optimal results from the Microtek scanning software and user s manual you should...

Страница 3: ...PositioningTransparent Film 12 Using the Glass Holder 13 Using the Other Film Holders 14 A Using the 35mm Slide Holder 15 B Using the 35mm Filmstrip Holder 15 C Using the 6 x 9 cm Film Holder 17 D Usi...

Страница 4: ...iv...

Страница 5: ...ou in the installation and operation of your scanner and the information provided covers both Macintosh and PC environments System Requirements CD ROM drive for installing software Color display with...

Страница 6: ...ke sure that the scanning surface will not be exposed to direct sunlight or other sources of bright light Avoid placing the scanner close to sources of extreme cold or heat Avoid connecting the scanne...

Страница 7: ...ct Microtek s customer service department 1 ArtixScan 1800f scanner 2 1 FireWire card 2 2 FireWire cable 2 3 USB 2 0 cable backward compatibility to USB 1 1 2 4 Power cord 2 5 Microtek CD ROM ScanWiza...

Страница 8: ...ler Scanner lid Glass surface Upper scan bed Vertical ruler Taking a closer look Transparency tray Lower scan bed Power button Power indicator green Transparency Ready indicator amber Reflective Ready...

Страница 9: ...ing slightly from the bottom of the scanner Shipping the Scanner If you have to transport the scanner the scanner must be locked To lock the scanner follow the steps below 1 Turn off the scanner if yo...

Страница 10: ...install ScanWizard Pro the installer program will install the Color Matching System driver program and ask you to perform Color Matching for your monitor and printer The Color Matching System feature...

Страница 11: ...pped with a built in FireWire port This port should be designated with the FireWire symbol shown to the left For PC users the FireWire card should be installed and should work properly in your compute...

Страница 12: ...and connect the other end of the cable to the scanner s FireWire port 3 Press the power button on the front panel and wait for the lights to stop blinking and stay on steady The scanner will be detect...

Страница 13: ...B 2 0 add on card that works properly in your computer For more details on how to install the Hi Speed USB 2 0 add on card in your computer please refer to the documentation that came with your purcha...

Страница 14: ...users with a Hi Speed USB 2 0 card installed For PC users with a built in USB port 3 Press the power button on the front panel and wait for the lights to stop blinking and stay on steady The scanner...

Страница 15: ...ou use the upper scan bed of the ArtixScan 1800f The upper scan bed is used for scanning reflective materials such as photos and prints 1 Open the scanner lid Note To scan a book or thick materials do...

Страница 16: ...is used to scan non standard sized transparent film Caution Make sure that the calibration slit faces the front of the scanner when you insert the holder into the transparency bay the drawer of lower...

Страница 17: ...holder 2 Place the vinyl strip on the edges of the transparency to secure the film in place 3 Insert the holder all the way into the transparency bay the drawer or lower compartment of the scanner Ca...

Страница 18: ...cular type of standard sized film For instance use the 4 x 5 film holder to scan 4 x 5 film or use the 35mm filmstrip holder to scan 35mm filmstrips 1 1 1 2 1 1 1 2 2 2 2 1 1 1 2 1 2 2 2 3 2 4 2 5 2 6...

Страница 19: ...lace the slide holder in the Main Holder 3 Insert the whole assembly into the transparency bay the drawer or lower compartment of the scanner B Using the 35mm Filmstrip Holder Two strips of six frames...

Страница 20: ...p s frame by frame partitions 2 Put the filmstrip holder into the Main Holder 3 Insert the whole assembly into the transparency bay the drawer or lower compartment of the scanner Frame by frame partit...

Страница 21: ...everal different film sizes of transparencies including 6 x 4 5 cm 6 x 6 cm 6 x 7 cm and 6 x 9 cm 1 Place the film into the holder a Push on the side to open the lid b Place the film in the holder c P...

Страница 22: ...pieces of 4 x 5 film at a time 1 Place the film into the holder a Push on the side to open the lid b Place the film in the holder c Pull down the side to close the lid 2 Put the film holder into the...

Страница 23: ...the Start menu in Windows The first time you launch ScanWizard Pro you will be asked to perform Color Matching for your monitor and printer 2 Once ScanWizard Pro is launched go to the Preview window...

Страница 24: ...ginal bring up the Settings Window and select None on the Descreen options menu To scan printed material on the Descreen options menu select the suitable descreen level Newspaper Art Magazine etc 7 If...

Страница 25: ...ion are included in the scanner accessories package The calibration target is very delicate and must be handled carefully as follows Gently remove the target from its protective sleeve and avoid touch...

Страница 26: ...target position so that it is horizontally in the center of the glass surface B Positioning the Transparent Target 1 Place the target face down in the 4 x 5 Film Holder Note that the side of the targ...

Страница 27: ...en instructions to generate your ICC profile Choose the proper target media select Reflective for reflective material otherwise select Positive Select the date code and target type to match your targe...

Страница 28: ...h ScanWizard Pro 2 From the Preview window click the Scan Material icon Select the Reflective icon for reflective materials select the Positive Transparency icon Positive Film for transparencies and s...

Страница 29: ...ion Optical 1800 dpi x 3600 dpi Interpolated 14400 dpi x 14400 dpi Dimensions L x W x H 24 7 x14 8 x5 1 627 38x375 92x129 54mm Weight 26 4lb 12kg Voltage AC100Vto240V 47 63Hz Environment Operating tem...

Страница 30: ...not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Responsible Party Loi Han 3715 Doolittle Drive Redondo...