6

5.

  Now rotate dial to ‘Direction Change Press PB’.  

  If you want to change motor direction, press 

PB

, and a green light will appear to show the 

  direction has been changed. Otherwise rotate dial to ‘Motor Setup’.

direction change 

direction change 

press pb

press pb

direction 

direction 

changed

changed

6.

  Rotate to ‘Setup System Press Button’, now press 

PB

 and the gate will close until it reaches 

  end stop.

setup system

setup system

press button

press button

setting

setting

close

close

4.

  Now rotate the dial to display ‘Drive Motor 1 Close’.  

  You can drive the motor in the close direction by holding down the 

PB

 button, or holding  

  down button 

1

 on a coded remote.

drive motor 1

drive motor 1

close

close

Note: 

Close stop must be fitted to motor arm for articulated arm style. For linear motor we 

use the fully extended internal stop.

system not setup

system not setup

12 9 volts

12 9 volts

1.

  Power up display, it will read ‘System Not Setup’. Now press 

PB

 to enter set up menu.

1. e-Gate Single Set Up – Encoder

system type

system type

encoder

encoder

2.

  First display is ‘Encoder’. Press 

PB 

to select (or rotate dial to select a different program).

drive motor 1

drive motor 1

open

open

3.

  The screen will now display ‘Drive Motor Open’. You can drive the motor in the open  

  direction by holding down the 

PB

 button, or holding down button 

1

 on a coded remote.

Содержание e-GATE

Страница 1: ...INSTRUCTION MANUAL enquiries microtechdesigns com au microtechdesigns com au ...

Страница 2: ...with backlight Rotary switch for easy menu access Compatible with e Loop and e Loop Mini e Keypad e Remote and e TX Multiple programs Encoder Limit Switch 5 Wire Limit Switch 2 Wire and End Stop Multiple program functions including speed control ramp up and ramp down adjustment times multiple force menu settings auto close and secure close functions just to name a few Menu Index 4 e Gate Single Se...

Страница 3: ...otor drive Multi frequency communication Single 12VDC motor drives up to 10 Amps Short circuit protection Reverse battery protection Built in solar charger Exceptionally low standby current 8 m a Specifications DISPLAY DISPLAY PB Push Button Dial ...

Страница 4: ...K OUT MENU Allows you to lock out Auto close or a particular device such as an e Loop or e Keypad using the e Remote lock and unlock buttons E LOOP SETTINGS MENU Allows you to change settings and diagnose operation of a coded e Loop E RADAR SETTINGS Allows you to change settings and diagnose operation of a coded e Radar SET PB INPUT TO Allows you to change the default Push Button inputs to OPEN or...

Страница 5: ...ll close after set time even if it has not reached the open position PEDESTRIAN MENU PEDESTRIAN MODE Allows you activate Pedestrian function PEDESTRIAN Allows you to change opening position PED AUTO CLOSE Allows you to activate Pedestrian Auto Close function PED AC TIME Allows you to adjust Pedestrian Auto Close time LOCK MENU LOCK TYPE Allows you to select Pulse Hold or courtesy function COURTESY...

Страница 6: ...ose direction by holding down the PB button or holding down button 1 on a coded remote drive motor 1 drive motor 1 close close Note Close stop must be fitted to motor arm for articulated arm style For linear motor we use the fully extended internal stop system not setup system not setup 12 9 volts 12 9 volts 1 Power up display it will read System Not Setup Now press PB to enter set up menu 1 e Gat...

Страница 7: ...pen pos set open pos set closing closing 0 5 A 3 0 a 0 5 A 3 0 a 8 Once gate reaches the closed position Setup Complete will display then after 2 seconds the main screen will display system closed system closed 12 9 volts 12 9 volts setup setup complete complete After motor has been stationary for 10 seconds the screen will display Open Position Set Once gate board has stored the closed position t...

Страница 8: ...up direction change direction change press pb press pb direction direction changed changed 2 e Gate Single Set Up Limit Switch 5 Wire system not setup system not setup 12 9 volts 12 9 volts system type system type limit 5 wire limit 5 wire First display is Encoder rotate dial to select Limit 5 Wire and press PB 2 Screen will display Test Limits You can activate limit switches by hand to ensure you...

Страница 9: ...press button setting setting close close 7 Once gate reaches the close limit the gate will open then close opening opening 239 239 closing closing 239 239 8 Once gate reaches the closed position Setup Complete will display then after 2 seconds the main screen will display system closed system closed 12 9 volts 12 9 volts setup setup complete complete ...

Страница 10: ...lect Limit 2 Wire 1 Power up display it will read System Not Setup Now press PB to enter set up menu System Type 2 Screen will now display Drive Motor Open You can drive the motor in the open direction by holding down the PB button or button 1 on a coded remote drive motor 1 drive motor 1 open open 3 Now rotate dial to display Drive Motor 1 Close You can drive the motor in the close direction by h...

Страница 11: ...n then close opening opening 239 239 closing closing 239 239 7 Once gate reaches the closed position Setup Complete will display then after 2 seconds the main screen will display system closed system closed 12 9 volts 12 9 volts setup setup complete complete ...

Страница 12: ...how the direction has been changed Otherwise rotate dial to Motor Setup direction change direction change press pb press pb direction direction changed changed 4 e Gate Single Set Up End Stop system type system type end stops end stops system not setup system not setup 12 9 volts 12 9 volts First display is Encoder rotate dial to select End Stops Now press PB and a green light will appear 1 Power ...

Страница 13: ...n then close opening opening 239 239 closing closing 239 239 7 Once gate reaches the closed position Setup Complete will display then after 2 seconds the main screen will display system closed system closed 12 9 volts 12 9 volts setup setup complete complete ...

Страница 14: ...ow press the Remote button a second time to confirm and the e Gate board will display Coded and the remote number Note To exit Code Learn you can press PB again or wait 10 seconds and the board will automatically exit back to main screen confirm confirm rem 2 rem 2 coded coded rem 2 rem 2 3 Now you can take a second remote and follow the same sequence or press the Remote button for a third time an...

Страница 15: ...ce 2 Now place the e Loop close to the antenna of the board then press and release PB If pairing is successful the screen will display Loop number Paired If not successful Code Learn will be displayed To exit Code Learn press PB again or wait 10 seconds and it will automatically exit to the main menu ...

Страница 16: ...16 enquiries microtechdesigns com au microtechdesigns com au ...

Отзывы: