III. Operation Process
1. How to adjust the pressure:
1. Connect the heat press with air compressor or air sources.
2. Lift up the cap of air valve as the picture shown
3. Revolve the cap anticlockwise, the air pressure goes down; contrariwise, the air pressure goes up; when you
finish the pressure adjustment, push down the cap.
4. Suggested air pressure is 0.4~0.5Mpa/ 70-80Psi. It depends on the transfer materials.
2. Set temperature required
Turn on power switch, temperature
light is ON. The digital display shows
.
Press
button, the
light is
on (C denotes Celsius). Press
arrows “
△
” or “
▽
” to select “
℃
” or
“
℉
” (F denotes Fahrenheit)
according to your habits.
Press
button, the temp
light
is on. Select with arrows the
temperature according to different
transfer material (Normally
180
℃
~200
℃
)
3. Set time required
Hot Port
Cold Port
Note: There are two small port in
front side of the digital display.
Press
button after temperature
setting and the
time light is
on. Select with arrows the time
according to different transfer
material.
Press
button after time setting;
the display shows the temperature
starts to rise. “CD-L” shows the time
counting down during your transfer.
If the real temperature is lower than
digital controller shown, you can
adjust the “hot port”; Clockwise to
raise temperature; anticlockwise to
reduce temperature.