3.2 Description of the Signals
Pulse input, UP / DOWN Switching
Status of the second pulse input specifies the counting direction of the
first pulse input. Status HIGH -> upwards, status LOW -> downwards
Incremental Input
Differential inputs (5 V level) for two phase-delayed signals. The upwards or
downwards counting happens according to the phase shift of the both signals.
IDx, phase a and phase B can be inverted with MKS software.
Reset / Preset
The reset/preset input can be configured with MKS software for edge
detection or status of input. The counter is always set to the preset val-
ue. The input acts as reset input, if preset value = 0. The preset value
can be set vial BCD preset values, MKS software, frame or script.