miface EN
Universal Interface with Ethernet TCP/IP / Serial Interface RS232/485/422
Page
5
microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden
Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, [email protected]
3.1 Configuration
3.1.1 Ethernet Interface
The interface is preset with the following network settings:
IP Address: 192.168.4.200
Net Mask:
255.255.255.0
Port:
10001
To change these parameters, proceed as follows:
Advice for Windows 7 users:
The Telnet client must be activated:
Start -> Control Panel -> Programs -> Turn Windows features on or off
-> Telnet Client
•
Switch the supply power for the interface on and connect it to the network
hub with an RJ45 cable (1:1 cable) or directly to a PC (crosslink cable).
•
Start the “MS DOS entry prompt” at your Windows PC.
With Windows 7 you must have extended rights:
Start -> All Programs -> Accessories -> double-click at Command Promp
-> Run as Administrator
•
Enter the desired IP address for the interface to the ARP table:
ARP -S XXX.XXX.XXX.XXX xx-xx-xx-xx-xx-xx <CR>
XXX.XXX.XXX.XXX : desired IP address
xx-xx-xx-xx-xx-xx
: Ethernet MAC address of the interface
(see label at the housing)