Microsound MF A02 Скачать руководство пользователя страница 4

MFA0X.doc  

16-04-08 

Page 4 of 6

3.2.   Door Station Connections 

1.

 

+15vdc   

Power from power supply 

2.

 

Gnd  

 

Ground from power supply 

3.

 

DS1 

 

Door strike.  Normally Open contact 

4.

 

DS2  

Door 

strike 

 

5.

 

Gnd  

 

To handset.  Common to all handsets 

6.

 

Tx  

 

Transmit to handset.  Common to all handsets 

7.

 

Rx 

 

Receive to handset.  Common to all handsets 

 

3.3. Power 

Supply 

Connections 

1.

 

+15vdc      

Connect to door stations  

2.

 

Gnd 

   

Connect to door stations  

3.

 

Neutral  

Mains (220vac) 

4.

 

Live        

Mains (220vac) 

 

4. Audio 

level 

adjustments 

1.

 

TX adjust level from the door station to the handsets. 

2.

 

RX adjusts level from the handsets to the door station. 

3.

 

These adjustments are best set when the complex system is installed. 

5. Technical 

Information 

5.1. Cable 

requirements 

Three common wires to each handset plus one call wire per handset. Maximum accumulated 
length 500  metres using 0.8mm fire alarm cable. 
 

5.2. Door 

Station 

              MFA02 size        :              136mm high x 101mm wide x 80/60mm deep         
              MFA08size         :              161mm high x 156mm wide x 80/55mm deep 
              MFA20 size 

:              292mm high x 156mm wide x 80/55mm deep  

Mounting :  

Surface. 

Finish   

 Weather proof box constructed of mild steel and powder coated. The 

front is constructed of anodised aluminium. 
 
Power:  15 vdc 70 ma 

5.3. Handset 

 

Size 

 

215 mm x 96 mm wide x 65 mm high. 

Power   

15 vdc   10 ma (idle). 

    15 

ma 

(ringing) 

6. 

First Line Service 

 
 
 
 

Отзывы: