Troubleshooting
Troubleshooting
The following troubleshooting scenarios provide high-level guidance on how to solve a range
of potential problems with the SyncServer.
n
A bullet is a proposed solution. The user should try each solution in turn until the problem
is solved.
n
A numbered step is a procedure. The user should complete the procedure to solve the
problem.
For additional help, contact
Microsemi Customer Assistance
(on page 5).
Passwords
You've tried logging in and the password doesn't work.
n
Passwords are case sensitive. Check that that
Caps Lock
isn't on.
n
Use the
Recover Password
feature, if it is available and configured.
n
Have another user log in and change your password settings.
n
If all else fails, restore the factory default configuration using the hardware jumper. See
Restoring the Factory Default Configuration
(on page 167).
See also:
Properties of User Names and Passwords
(on page 23)
AlarmsandNotification
You're not receiving alarm notifications by email or snmp.
n
Check that the alarm notification settings are enabled, as shown in the
Factory Default
Settings for Alarms
(on page 89) topic.
n
To receive SNMP traps, verify that the
NETWORK - SNMP
and
NETWORK - SNMP Traps
pages are configured correctly.
n
To receive email notification, verify that the
SERVICES - Email
page is configured correctly.
n
Verify that LAN1 is configured with a valid DNS server address.
NTPClients
The NTP clients can't reach or synchronize with the SyncServer. On the SyncServer:
n
The
Network
LED on the front panel should be green. Otherwise, check the physical net-
work port connections. Also see
Status LEDs
(on page 15).
n
Check the configuration of the network ports on the
NETWORK - Ethernet
page, described
in
Configuring the Network Ports
(on page 149).
n
If the
Sync
LED on the front panel is red, the SyncServer is unsynchronized and NTP cli-
ents won't synchronize to it. Configure the SyncServer with a valid reference input and/or
NTP server/peer associations. Also see
Using GPS
(on page 140),
Using the Other
Input References
(on page 150), and
Adding Server Associations
(on page 150).
997-01520-02 Rev. F1
..........................................................................
Page 151