Functions and Features

 

The high-power gigabit single port PoE (Power over Ethernet)  
PD-9501G/48VDC Midspan injects power over data-carrying Ethernet 
cabling. It maintains the IEEE802.3at and IEEE802.3af standard, while 
doubling the output power (60W). These power levels allow usage by a 
new range of Ethernet-based applications such as Video Phones, 802.11n 
access Points, WiMAX

TM

  Transmitters, PTZ Cameras & more. The 

         

PD-9501G/48VDC 

"DATA & POWER OUT"

  port is designed to carry 

Gigabit Ethernet data & power over a standard CAT5/5e/6 cable, delivered 
through all 4-pairs  

 

EMC Compliance

:  

  FCC Part 15 class B  

  EN55022 class B 

  EN55024  

Safety compliance: 

  UL60950-1  

  GS compliance 

Preliminary Steps 

  Ensure 

DC

 power is applied to the PoE Midspan, using stranded tinned 

copper 16 AWG cables for each terminal (rated for 2 Amperes), with an 
appropriate separate ground connection (when needed). 

  Ensure that the output Ethernet cable is connected to the 

"DATA & 

POWER OUT"

 port. 

 

Verify that an Ethernet compatible device is connected to the output 
Ethernet cable, and that it is arranged to receive power on its Ethernet 
port.

 

WARNING  

Do not use a cross over cable between the PoE Midspan output port and the 
load device.

 

Installation

 

The PoE Midspan may be located on a desktop/ floor  or mounted on a 
wall/bench using the rear side mounting holes. 

  Associated Ethernet wiring shall be limited to inside of the building 

  Power inlet cable and chassis connection cable are not supplied with the 

product 

Before mounting the PoE Midspan to a fixed location: 

 

  Make sure the  PoE  Midspan  and  the airflow to it,  are not covered or 

blocked  by  any foreign objects. Keep the PoE  Midspan  away from 
excessive heat and humidity and ensure it is free from vibration and 
dust. 

  Ensure that the total Ethernet cable length does not exceed 100 meters 

(333 feet). The PoE is not a repeater and does not amplify the Ethernet 
data signal. 

  A splitter may be used if desired; ensure that the splitter is connected 

close to the PD but not to the Midspan. 

  There is no “On-Off” switch; simply plug the PoE Midspan into a 

DC

 

power source. 

Installing the Unit 

  Verify that 

DC

 power source is off. 

  If supplemental earth ground is replaced, apply 5Lb/In torque (optional). 

  Tighten the 2 connector screws (see Figure 2). 

  Connect the PoE Midspan PWR  connector to stranded  tinned  copper 

cables, 16 AWG for each terminal (rated for 2 Amperes), and tighten the 
2 Cable inlet screws (See Figure 2). 

  Connect the “DATA IN” jack (input) to the data source (switch)  and the 

“DATA & POWER” jack (output) to the terminal (PD) (See Figure 3).

 

  Turn on the 

DC

 power source and check the appropriate LED indicators 

to verify that power is on 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2: PoE Midspan Power Connector 

            

 
 
 
 
 
 
 
 
 
 
 

 
 
 
  

 

Figure 3: PoE Midspan Ports

 

Indicators

  

Main LED 

Behavior  

OFF 

Power OFF indication

 

Green on 

Power ON indication (power is active)

 

Port LED 

Behavior  

OFF 

Disconnection, or no detection, or no load is connected. 

Green on 

Power supplied over data and spare pairs  

Blinking green at 1Hz rate 

Overloaded / shorted  

 

13B

Specifications

 

16B

Environmental Specifications 

Mode

 

Temperature

 

Humidity

 

Operating 

-20 to 40°C 
-4 to 104°F 

10 to 90%  
(no condensation allowed) 

Storage 

-20 to 70°C 
-4 to 158°F 

10 to 90%  
(no condensation allowed) 

 

14B

Electrical Specifications 

Operation Voltage 

36-60VDC  

Input Current (max.) 

2 Amperes 

Available Output Power (max.) 

60 Watts  

Nominal Output Voltage 

53.5 to 55.5VDC 

 

17B

Ethernet Interface     

Input (DATA IN):  
Ethernet 10/100/1000Base-T 

RJ45 female socket 

Output (DATA & POWER OUT):  
Ethernet 10/100/1000Base-T, 
 plus 55VDC 

RJ45 female socket, with DC voltage 
on wire pairs 1-2, 3-6, 4-5 & 7-8.  

 

 

   Troubleshooting 

Symptom 

Corrective Steps 

 
PoE Midspan  
does not 
 power up

 

1.  Ensure  that  the  installation was in 

accordance with the "Installing the 
Unit" section in this user guide.   

2.  Ensure that the power source 

supplies  between  36-60VDC  and can 
carry out 80W.   

3.  Remove and re-apply power to the 

PoE Midspan, and verify that the main 
led  indicator on the front panel is 
continuously lit. 

 

The PD  
(Powered 

Device) 

does not 

operate

 

1.  Check the Midspan’s LED indicators. 

2.  Remove and re-apply power to the 

PoE Midspan, and check the led 
indicators during power up sequence.   

3.  Verify that the PD is designed for PoE 

operation. 

4.  Verify  that  you are using a standard 

UTP/FTP  category 5/5e/6, straight-
wired four pairs cable. 

5.  Verify that the PD is connected to the 

"DATA & POWER OUT" port.  

6.  If an external power splitter is in use, 

replace it with a splitter known as 
good. 

 
The end device 

operates, 
but there is 
no data link 

1.  Verify that the port LED  indicator on 

the front panel is continuously lit. 

2.  Verify  that  you are using a standard 

UTP/FTP  Category 5/5e/6, straight-
wired cable. 

3.  Verify that the Ethernet cable length is 

less than 100 meters from the POE 
source to PD. 

4.  Ensure  that the input Ethernet cable 

is connected to the "DATA IN" port. 

5.  If  a splitter is in use, replace it with a 

splitter known as good. 

 

 

Отзывы: