Microsemi 9001G-40/SP Скачать руководство пользователя страница 2

Functions and Features 

The High-Power Gigabit single port PoE (Power over Ethernet) PD-
9001G-40/SP Midspan injects power over data-carrying Ethernet 
cabling. It supports the IEEE802.3at and IEEE802.3af standards, 
while increasing the output power to 40W. These power levels allow 
usage by a new range of Ethernet-based applications such as Video 
Phones, 802.11n Access Points, WiMAX Transmitters, PTZ Cameras 
& more. The PD-9001G-40/SP Data & Power Output port is designed 
to carry Gigabit Ethernet data & power over a standard CAT5e cable, 
delivered through all 4-pairs (Alt A: pins 1,2 (-) & 3,6 (+), Alt B: 4,5 (+) 
and 7,8 (-)).  

 

PD-9001G-40/SP EMC Compliance

:  

 

FCC Part 15 class B and EN55022 class B 

 

EN55024  

 

VCCI 

PD-9001G-40/SP Safety Compliance

:  

 

UL/cUL per EN60950-1 

 

GS mark 

PD-9001G-40/SP Lightning Protection

:  

 

Designed to meet GR-1089-CORE lightning protection demands. 

Preliminary Steps 

 

Ensure that AC power is applied to the PoE Midspan, using an 
operational AC cable with an appropriate ground connection. 

 

Ensure that output Ethernet cable is connected to the Data& 
Power Out port. 

 

Verify that power ready Ethernet compatible device is connected. 

WARNING  

Do not use cross over cable between the PoE Midspan output port 
and the load device

 

Installation

 

The PoE Midspan may be located on a desktop or wall/bench 
mounted using the rear side mounting holes. 

Before mounting the PoE Midspan to a fixed location: 

 

 

Do not to cover PoE Midspan or block the airflow to the PoE 
with any foreign objects. Keep the PoE Midspan away from 
excessive heat and humidity and free from vibration and dust. 

 

Ensure that the cable length from Ethernet network source to 
the terminal does not exceed 100 meters (333 feet). The PoE 
is not a repeater and does not amplify the Ethernet 
data signal. 

 

Use a splitter if desired; ensure that the splitter is connected 
close to the terminal and 

not

 on the Midspan! 

 

No “on-off” switch exists; simply plug the PoE Midspan into an 
AC power source. 

Installing the Unit 

1.  

Connect the PoE Midspan to an AC outlet (100-240VAC), using a 

standard power cord. 
2.  Connect the Data In jack (input) to the remote Ethernet network switch's 
Patch panel and the Data & Power Out jack (output) to the terminal. 
3.  Connect the chassis screw connection to the main chassis infrastructure 
as illustrated on Figure 2.

  

4. 

Associated Ethernet wiring shall be limited to inside of the building.

 

 

Ethernet

Cat

5

 

Cable  

Terminal

 

Port

 

Connectivity

 

Indication

AC

 

Input

 

Connectivity

 

Indicator

 

Figure 3: Connecting the PoE Midspan

 

Indicators

 

LED

 

AC (Main)

 

Port

 

Green

 

Indicates that the 
power is ON 
(Power is active) 

Indicates that a 
remote terminal 
is connected 

Green Blinking 
at 1 Hz

 

Overload or short 
circuit 

Green Blinking 
at 4 Hz

 

Internal Fault 
Condition 

12B

Specifications

 

15B

Environmental Specifications 

Mode

 

Temperature

 

Humidity

 

Operating 

0 to 40°C 
32 to 104°F 

10 to 90%  
(no condensation 
allowed) 

Storage 

-20 to 70°C 
-4 to 158°F 

10 to 90%  
(no condensation 
allowed) 

 

13B

Electrical Specifications 

Input Voltage 

100-240 VAC  
(50-60 Hz) 

Input Current (110 - 220VAC) 

0.8 Ampere 
(max) 

Maximal Available Output Power 

40 Watts  

Nominal Output Voltage 

52 to 56 VDC 

 

16B

Ethernet Interface 

Input (Data In):  
Ethernet 10/100/1000Base-T 

RJ45 female 
socket 

Output (Data & Power Out):  
Ethernet 10/100/1000Base-T, plus 
55VDC 

RJ45 female 
socket, with DC 
voltage on wire 
pairs 7-8 and 4-
5.  

 

14B

Troubleshooting

 

Symptom 

Corrective Steps 

Midspan 
does not 
power up 

1.  Verify that a reliable cord is in 
use. 
2.  Verify that the voltage at the 
power inlet is between 100 and 
240 Vac. 
3.  Remove and re-apply power to 
the device and check the indicators 
during power up sequence. 

 

A port 
indicator is 
not lit and 
the PD 
does not 
operate 

1.  Verify that Midspan detects a 
PD. 
2.  Verify that the PD is designed 
for PoE operation. 
3.  Verify that you are using a 
standard Category 5/5e/6, straight-
wired cable, with four pairs. 
4.  If an external power splitter is in 
use, replace it with a known-good 
splitter. 
Ensure input Ethernet cable is 
connected to the Data In port. 
5.  Verify that the PD is connected 
to the Data & Power port.  
6.  Try to reconnect the same PD 
into a different Midspan. If it works, 
there is probably a faulty port or 
RJ45 connection. 
7.  Verify that there is no short over 
any of the twisted pair cables or 
over the RJ45 connectors. 

The end 
device 
operates, 
but there is 
no data 
link 

1.  Verify that the port indicator on 
the front panel is continuously lit. 
2.  If an external power splitter is in 
use, replace it with a known-good 
splitter. 
3.  Verify that for this link you are 
using standard UTP/FTP Category 
5 straight (non-crossover) cabling, 
with all four pairs. 
4.  Verify that the Ethernet cable 
length is less than 100 meters from 
the Ethernet source to the 
load/remote terminal. 
5.  Try to reconnect the same PD 
into a different Midspan. If it works, 
there is probably a faulty port or 
RJ45 connection. 

 

 
 

Отзывы: