MS-850 Raster Scanner User’s Manual
3-5
3–Ser
ial
Conf
ig.
For example,
<Kc1><Kh1><Ko1><A>
enables LRC, sets End of Read Cycle mode
to New Trigger, enables Narrow Margins and resets the data buffers (without saving the
changes for power-on).
Serial Command Status Request
The status of serial commands can be requested by entering the command followed by
a question mark. For example, send
<Ke?>
to request the status of Postamble. Com-
mands KT?, KV?, KW?, KX?, and KU? are used to request the status of groups of serial
commands.
Loss of Communications
Making changes to communications parameters such as Baud Rate, Parity, Stop Bits,
LRC, etc. without corresponding changes in linked device(s) can result in the loss of
menu access. If this should occur, try ESP
Auto Baud
command or restore defaults.
Caution
:
Defaulting the scanner will reset all standard configuration parameters except
Scanner Type, Scans per Second, and Gain Adjustment to their original default values.
Note
:
Power must be available to the scanner during the default procedure.