background image

MS-820 Industrial Bar Code Scanner Quick Start Guide

7

Step 6 — Position Symbol and Scanner

1. Set up a symbol at the scanning distance you will be using in your 

application.

Note: If using an I 2/5 symbol, verify that the number of characters 

in the symbol being scanned matches the symbol length enabled for 

the I 2/5 symbol type (default is 10 and 6).

2. Avoid bright light or IR light from other sources, including other 

readers.

3. Pitch the symbol or reader at a minimum of ±15° to avoid specular 

reflection (the return of direct, non-diffused light).

Scanner and symbol positioning

Note: Code 39 is the default symbol type enabled. If you are uncer-

tain as to your symbology type, enable all symbologies by selecting 

the 

Auto Discriminate

 macro in Terminal mode.

Pitch

axis

Bar code

label

Tilt

axis

Skew

axis

Scan line

Scanner

Содержание MS-820

Страница 1: ...P Easy Setup Program to configure and control your MS 820 Industrial Bar Code Scanner In addition to ESP you can send commands to your scanner by serial command and by the scanner s embedded menus For a full explanation of the MS 820 s commands and features refer to the Help section of ESP or contact your Microscan sales representative for the MS 820 Industrial Bar Code Scanner User s Manual avail...

Страница 2: ...em Part Number Description 1 FIS 0820 XXXXG MS 820 Industrial Bar Code Scanner 2 A Host Computerb b With either a terminal communications program or Microscan s ESP which runs on Windows 98 or higher 3 61 300026 03 DB 25 Null modem configuration cable plug to DB 9 socket 6ft c or a 25 pin cable to the 25 pin port c If using another host cable make certain that it does not have RTS CTS connected to...

Страница 3: ...make certain that you connect transmit pins to receive pins 3 Connect the IB 131 4 at the HOST 25 pin connector to the com puter 2 via a null modem cable 3 1 4 Connect the power sup ply 6 to the IB 131 s POWER connector 5 Connect power to the system 1 When wiring the IB 131 to a Host Computer that has a 25 pin connector cross pins 2 and 3 When wiring the IB 131 to a Host Computer that has a 9 pin ...

Страница 4: ...se ESP Software from the main menu 3 Launch Setup exe under ESP and follow the prompts If downloading from the web 1 Go to http www microscan com downloadcenter 2 Create a new myMicroscan member account or if you are already a member enter your user name and password 3 Click the Download Software link and extract the latest version of ESP to a directory of your choice Note where your ESP exe file ...

Страница 5: ...ox select your model If you do not want to make this selection every time you load ESP uncheck Show this window at Startup 2 Select the default name MS 820 1 for example or type in a file name of your choice and click OK 3 Click Yes when the following dialog box appears Note If you need to select another model later you can find it in App Mode under Model on the menu bar ...

Страница 6: ...t 2 Click the Start button When connected the scanner s settings will be loaded into ESP and the CONNECTED message will appear in a green box in the status bar at the bottom right of your screen 3 If the connection fails enable a different Com Port check connec tions and try again Tip If you do not see the CONNECTED or DISCONNECTED message at the bottom of your dialog try expanding the ESP window ...

Страница 7: ...the I 2 5 symbol type default is 10 and 6 2 Avoid bright light or IR light from other sources including other readers 3 Pitch the symbol or reader at a minimum of 15 to avoid specular reflection the return of direct non diffused light Scanner and symbol positioning Note Code 39 is the default symbol type enabled If you are uncer tain as to your symbology type enable all symbologies by selecting th...

Страница 8: ... in Setup Mode 1 Click the Test button in Setup Mode to begin the read rate test 2 Follow the instructions on the Setup Mode screen 3 To end the read rate test click the Stop button Note If the reader is in the default Continuous Read mode it will read and beep repeatedly as long as a readable symbol remains in the read range and as long as the Read Cycle configuration has not changed By Serial Co...

Страница 9: ...click the App Mode button To return to Setup Mode click the Setup Mode button By Serial Command From your terminal program or the Terminal screen in ESP you can enter serial commands and configuration and utility com mands Note You can learn the current setting of any parameter by inserting a question mark after the number as in K100 To see all K com mands send K ...

Страница 10: ...10 MS 820 Industrial Bar Code Scanner Quick Start Guide ...

Отзывы: