Step 6 — Connect

To connect using the Connection Wizard:

• Click 

Connect

 on the menu toolbar, and then select 

Connection Wizard

.

• Select the communication interface required by your application.
• Configure settings as required by the application, and click 

Connect

.

• When a connection is established, the green indicator in the status bar at 

the bottom right of the screen will be visible:

Important:

 The imager is in 

Continuous Read Mode

 by default. For 

best connection results, be sure that no decodable symbols are within the 

imager’s field of view while attempting to connect.

Step 9 — Test Read Rate

Read Rate

 indicates the number of successful decodes per second 

achieved by the imager. 

Test Read Rate by EZ Button

1. To start the Read Rate test, hold down 

the EZ Button about three seconds 

until you hear 

three short beeps

. The 

20%

40%

, and 

60%

 LEDs will illuminate.

While the object is being inspected, the 

Read Rate LEDs will indicate the read 

rate percentage on the back of the unit.

2. To end the Read Rate test, press the

EZ Button and quickly release.

Test Read Rate by ESP

1. Click the 

Test

 button to start the Read 

Rate test and 

Stop

 to end it.

If a symbol has been successfully 

decoded, its data and related features 

will be presented in the field below the 

image display window. Also, while the 

object is being inspected, the Read 

Rate LEDs will indicate the Read Rate 

percentage on the back of the unit.

2. To end the test, click the 

Stop

 button.

Note:

 Read Rate can also be tested using the 

Read Rate 

interface in

Utilities

.

Test Read Rate by Serial Command

You can also start a test with the 

<C>

 or 

<Cp>

 command and end it with the 

<J>

 command.

MS-4Xi Read Rate 

LEDs and EZ Button

MS-4X Read Rate 

LEDs and EZ Button

Step 7 — Locate the Symbol 

Locate by ESP

• In 

ESP

’s 

EZ Mode

, click the 

Locate

 button to enable the blue target

pattern.

The symbol in the field of view will appear in the video view beneath the 

Locate

 and 

Calibrate

 buttons, and you will see the blue target

 

pattern

projected from the front of the imager.

• Center the target

 

pattern on the symbol.

At 2 to 3 inches, the pattern resembles an 

X

. At 3 to 6 inches, the

pattern resembles a 

V

.

Important: 

The entire symbol should fall within the field of view (FOV) of 

the imager. The field of view is what appears in 

ESP

’s 

Locate/Calibrate

window in 

EZ Mode

.

• Click the 

Stop

 button to end the 

Locate

 function.

Locate by EZ Button

If you are not connected to a host computer, the EZ Button allows you to 

locate the symbol in the imager’s field of view.
• Hold down the EZ Button for about one second and release when you 

hear one short beep. The amber 

20%

 LED will illuminate, and you will 

see the blue target

 

pattern projected from the front of the imager.

• Center the target

 

pattern on the symbol.

Note:

 To end all EZ Button functions, press the EZ Button once and 

quickly release.

Step 10 — Configure and Save

Click the 

App Mode

 button to make configuration changes to the imager.

The following modes are accessible by clicking the buttons at the top of the 

screen:

• Click the 

EZ Mode

 button to return to EZ Mode.

• Click the 

Autoconnect

 button to establish communication.

• Click the 

Send/Recv

 button to send or receive commands.

• Click the 

Switch Model

 button to open the model menu, or to return to

a previous model.

• Click the 

Parameters

 button to show the tabbed tree controls for

Communication, Read Cycle, Symbologies, I/O Parameters, Symbol 

Quality, Matchcode, and Diagnostics.

• Click the 

Setup

 button to access a Camera Setup tree control and Video 

view, Evaluate image captures, Calibrate the imager, set the Window of 

Interest, load capture settings and processing settings in the Configuration 

Database, set up output filters and parse symbol data in Ordered Output 

and Output Format, and control multiple read cycle functions in Dynamic 

Setup.

• Click the 

Terminal

 button to display decoded symbol data, and to send 

serial commands to the imager using text or macros.

• Click the 

Utilities

 button to test Read Rate, request or clear Counters, 

enable or disable the imager or send output pulses in Device Control, 

determine the Differences from Default in the current settings, add or

remove master symbol data in Master Database, and verify or update the 

imager’s Firmware.

Step 8 — Calibrate

Imager settings can be adjusted automatically for optimum performance 

by either the EZ Button or by 

ESP

.

During the calibration routine, the imager will flash its Read Rate       

percent LEDs and illumination LEDs while searching camera settings    

and determining the best configuration for decoding symbol data. Upon 

successful completion of this routine, a green LED pattern will flash brightly 

and illuminate the symbol. If unsuccessful, the imager will emit 5 short 

beeps and stop searching.

Calibrate by EZ Button

1. Hold down the EZ Button for about two seconds and release when 

you hear 

two short beeps

. The

 20%

 and 

40%

 LEDs will illuminate.

2. The imager will search camera settings to determine the best configuration 

for decoding symbol data.

Note:

 To end all EZ Button functions, press the EZ Button once and 

quickly release.

Calibrate by ESP

1. Click the 

Calibrate

 button.

2. The imager will search camera settings to determine the best configuration 

for decoding symbol data.
A successful calibration will display a green frame around the

symbol, and the following message will appear: “Uploading all reader 

parameters.” After a moment the symbol data will be presented in 

the field below the image display window.

Calibrate by Serial Command

Send 

<@CAL>

 from a terminal program to begin calibration.

Step 11 —Save Changes in ESP

To make changes to a configuration setting:

Saving Options

Send, No Save

. Changes will be lost when power is re-applied to the 

imager.

Send and Save

. This activates all changes in current memory 

and

 

saves to the imager for power-on.

1.

Left-click

 on the

+

 to expand the

desired tree.

2.

Double-click

 on

the desired

parameter and

click once in the

selection box to

view options.

3. Place your cursor in the selection box, scroll down to the setting 

you want to change, and 

click

 once on the setting.

4.

Left-click

 again on the open screen to complete your selection.

5.

Right-click

 on the open screen and select 

Save to Reader

 to

implement the command in the imager.