![Microsat WX3IN1 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/microsat/wx3in1/wx3in1_instruction-manual_1788255010.webp)
7. Description of configuration software
7.1. Opening a connection
After running the application, it is necessary to select the COM port of WX3in1
assigned by Windows. Then use OPEN PORT to connect to the device.
7.2. Reading configuration from the device
To read the configuration from the device you must use the READ CONFIG button,
after this action, the program will download current configuration values from WX3in1
internal memory.
7.3. Writing configuration to the device
After entering all parameters, such as a characters, objects, beacons, times, etc.,
choose WRITE CONFIG to upload current configuration to WX3in1 internal memory.
7.4. Firmware update
If there is a new software update, you should upload the new firmware attached
to WX3in1 Configurator software package. For this purpose, select the option UPLOAD
FIRMWARE, then open a new window for selecting files. From the directory WX3in1
Configurator / firmware select the file wx3in1_firmware_vXXX.hash (where XXX is the
next version of the firmware). After the update, disconnect the device from the
computer and cycle power.
After updating the firmware, you may need to re-upload configuration settings.
10