![MicroPower PrimePower Champ Pro 12/17 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/micropower/primepower-champ-pro-12-17/primepower-champ-pro-12-17_manual_1788205015.webp)
14
CHAMP PRO SERIES MANUAL 12/17
–
24/12
–
12/30
–
24/20
Idavägen 11 SE-352 46
|
+46 470 72 74 95
|
TYPES, CELLS & RATED CAPACITY
CHARGER
BATTERY TYPE
NUMBER OF CELLS
RATED CAPACITY
champ PRO 12/17
Lead acid batteries
6
50-220Ah
champ PRO 24/12
Lead acid batteries
12
40-200Ah
champ PRO 12/30
Lead acid batteries
6
100-400Ah
champ PRO 24/20
Lead acid batteries
12
80-300Ah
WARRANTY
•
Primepower warranty applies only to original purchaser within a period of 24 months from the date from
delivery.
•
Primepower guarantees that the product is in excellent condition upon delivery, unless comes full refund.
•
If the user has not conducted a proper installation or used the product incorrectly applies no warranty.
Warranty claim
To take advantage of warranty please contact your retailer.
Please have following information available:
•
Receipt
•
Model number
•
Product serial number
•
A brief description of the problem
WARNING!
Do not use this product without reading the entire manual! Incorrectly installed or use of the product
can sincerely damage the user, destroy the product or connected equipment. If the product is used the
wrong way, warranty may be void.
VARNING!
Temperaturstyrningen är beroende av sensorn som är monterad i den svarta kabelskon, klipps eller
korta kablaget av kommer denna funktion att försvinna. För att säkerställa den övriga funktionen av
laddaren skall ett 10k ohms monteras mellan den tunna svarta kabeln och minus. Anslut inte den tunna
minuskabeln direkt till minus, om temperatursensorn inte skall användas
–
isolera den tunna kabeln
WARNING!
The temperature sensor is integrated in the black connector. Cutting the minus (black) will void this
function.
If cutting the black cable a 10k NTC resistor shall be mounted between the thin black lead and minus.
Do not connect the thin black lead directly to minus, if temperature sensor is cut off and not intend to
be in used, please make sure to isolate the thin cable