Micronor MR361 Series Скачать руководство пользователя страница 14

MICRONOR 

automation components 

6. Warranty Information

Warranty 

MICRONOR warrants this product to be free from defects in material and workmanship for a 

period of 1 (one) year from date of shipment. During the warranty period we will, at our option, 

either repair or replace any product that proves to be defective. 

To exercise this warranty, write or call your local MICRONOR representative or contact 

MICRONOR headquarters. You will be given prompt assistance and return instructions. Send 

the instrument, transportation prepaid, to the indicated service facility. Repairs will be made 

and the instrument returned transportation prepaid.  Repaired products are warranted for the 

balance of the original warranty period, or at least 90 days. 

Limitations of Warranty 

This warranty does not apply to defects resulting from unauthorized modification or misuse of 

any product or part. This warranty also does not apply to Fiber Optic Connector interfaces, 

fuses, power supplies or AC line cords. This warranty is in lieu of all other warranties, 

expressed or implied, including any implied warranty of merchantability of fitness for a 

particular use. MICRONOR. shall not be liable for any indirect, special or consequent 

damages. 

Contact Information: 

For North and South America: 

Micronor Inc.   

Phone +1-805-499-0114 

750 Mitchell Road 

Fax 

+1-805-499-6585 

Newbury Park, CA 91320 USA 

Email 

sales@micronor,com

 

USA   

URL 

www.micronor.com

 

For Europe, Middle East, Asia, Africa: 

Micronor AG 

Phone +41-44-843-4020 

Pumpwerkstrasse 32  

Phone +41-44-843-4039 

CH-8015 Regensdorf  

Email 

[email protected]

 

SWITZERLAND 

URL 

www.micronor.ch

 

Page 14 of 19 

Содержание MR361 Series

Страница 1: ...INC are to be maintained in strict confidence no element or detail of this manual is to be spuriously used nor disclosed without the express written permission of MICRONOR INC All rights are reserved...

Страница 2: ...istory Revision Date Notes A 8 11 2014 Original Release English Author DNH Micronor Inc B 5 5 2015 Part Number Correction 9770 30 170 should be 9770 30 160 File Name 98 0361 01_MR361_Instruction_Manua...

Страница 3: ...ts not working but both LEDs On 12 5 2 Damaged In Shipment 13 6 Warranty Information 14 7 Specifications 15 8 Theory of Operation 17 9 Applications 18 9 1 Using unused XMTR inputs for signaling inputs...

Страница 4: ...he system works with both optical and magnetic encoders and operates with complete transparency to the motion control or motor drive system The system consists of a fiber optic transmitter XMTR and fi...

Страница 5: ...RVCR modules Models for 5 VDC or 10 30 VDC Encoders Models for RS422 TTL or HTL Push Pull line drive circuits EMI RFI immune fiber optic transmission link Encoder Link can reach up to 2 km Wide Syste...

Страница 6: ...dules do not have to be for the same encoder type Specifying a different RCVR module allows adapting signals to mismatched equipment encoder interfaces This is not a recommended practice but is a solu...

Страница 7: ...Mounting Modules on DIN Rail Figure 2 Modules mount on standard 35mm DIN rail Per Figure 4 first clip the fixed white side mount into one side of DIN rail Then snap the black spring loaded end into pl...

Страница 8: ...interface Be sure that the ST plug end face is clean before being installed into the ST receptacle Be sure to align the key on the plug with the slot on the receptacle before beginning to insert the...

Страница 9: ...pply Input same as Vin Uin Supply Input J2 1 Ground To Encoder Ground To Drive 2 Ub Supply To Encoder same as Vb Ub Supply Optional use same as Ub 3 Channel A From Encoder Channel A To Drive 4 Channel...

Страница 10: ...e displays status Figure 7 illustrates the meaning of the status LED for both XMTR and RCVR modules The status LEDs do not indicate if encoder signals are active The system transmits exactly what it s...

Страница 11: ...MICRONOR automation components Figure 7 Meaning of Status LED on XMTR and RCVR Modules Page 11 of 19...

Страница 12: ...nal power supply is rated correctly for the drive inputs Contact Micronor Sales for further assistance 5 1 3 RCVR Link Status LED Blinks Verify optical link cabling is properly connected and undamaged...

Страница 13: ...in the USA or Europe A Please retain the shipping container in case reshipment is required for any reason If you receive a damaged instrument you should 1 Report the damage to your shipper immediatel...

Страница 14: ...ty period or at least 90 days Limitations of Warranty This warranty does not apply to defects resulting from unauthorized modification or misuse of any product or part This warranty also does not appl...

Страница 15: ...OM1 62 5 125 m Graded Index MMF Link Distance Lesser of 6 dB or 2 km Optical Transmitter 850nm LED Input Sampling Rate Per Channel 2 MHz Electrical Specifications Specification Electrical Interface Mo...

Страница 16: ...ication Temperature Range 10 C to 65 C 14 F to 149 F Humidity 0 to 90 RH non condensing Ingress Protection IP40 Physical Specifications Specification Mounting 35mm DIN Rail Housing 18 x 111 x 88 mm 0...

Страница 17: ...e XMTR module are electrically multiplexed and then transmitted optically over a simplex fiber optic link The optical input signal to the RCVR is then converted back to the electrical domain and demul...

Страница 18: ...ling inputs Traditional encoders have only A B or A B Index outputs That leaves 1 D or 2 C D unused input channels that could be used for routing additional signaling inputs as shown in the example of...

Страница 19: ...MICRONOR automation components 10 Mechanical Reference Drawing The XMTR and RCVR modules are the same size and dimensions Dimensions in mm Page 19 of 19...

Отзывы: