Handeingabegerät Handbediengerät mit serieller Schnittstelle
www.micronor.ch
MR 175 Handheld Pendant, Manual
Specifications
Страница 1: ...f MICRONOR INC are to be maintained in strict confidence no element or detail of this manual is to be spuriously used nor disclosed without the express written permission of MICRONOR INC All rights ar...
Страница 2: ...Handeingabeger t Handbedienger t mit serieller Schnittstelle www micronor ch MR 175 Handheld Pendant Manual EC Declaration of Conformity...
Страница 3: ...formation Specifications Initial Preparation Unpacking and Inspection Damage Shipment Hardware Interface Communications Serial Interface Specification Data Exchange Protocol MR175 Transmission Packet...
Страница 4: ...ator MPG 100 pulses 360 Axis selector Rotary Knob Scale Selector Rotary Knob Feed Rate Continuous Adjust Potentiometer Start Momentary Button Tool in Out Momentary Button Jog Momentary Button Emergenc...
Страница 5: ...rned transportation prepaid Repaired products are warranted for the balance of the original warranty period or at least 90 days Limitations of Warranty This warranty does not apply to defects resultin...
Страница 6: ...Handeingabeger t Handbedienger t mit serieller Schnittstelle www micronor ch MR 175 Handheld Pendant Manual Specifications...
Страница 7: ...for and inspect each item before the carton is discarded In the event of a damaged instrument write or call MICRONOR INC in Newbury Park California Please retain the shipping container in case reship...
Страница 8: ...eller Schnittstelle www micronor ch MR 175 Handheld Pendant Manual Hardware Interface The hardware interface is accomplished by 8 wires terminated into a 10 pin Molex Connector Housing The customer pr...
Страница 9: ...termination characters such as LF Line feed or CR carriage return characters If additional characters are sent they will be ignored When the MR175 is powered up it transmits an identification string M...
Страница 10: ...ed properly the host computer shall acknowledge and request the packet again with an e command The e command instructs the MR175 to retransmit the previous packet again with the same data The host com...
Страница 11: ...ingabeger t Handbedienger t mit serieller Schnittstelle www micronor ch MR 175 Handheld Pendant Manual MR175 Transmission Packet All 11 bytes of the entire fixed length transmission packet are always...
Страница 12: ...Handeingabeger t Handbedienger t mit serieller Schnittstelle www micronor ch MR 175 Handheld Pendant Manual Commands to the MR175 signal characters...
Страница 13: ...is received other than c or e the MR175 will modify the last transmitted packet as follows and send the updated packet The start of transmission byte is then as ASCII S indicating a second attempt The...
Страница 14: ...n receiving a food command The following errors must be cleared sending command I initialize Error 1 Firmware Program Checksum Error Error 2 Watchdog Timer Error 25 Key pressed at start up When encoun...
Страница 15: ...five bits of the byte and an error count in bits 6 5 of byte The error count exist for multiple errors detection but only one can be reported Whenever errors are detected the count shall be set to a n...
Страница 16: ...ere are numerous sources for these devices such as Buy Converter http www buyconverter com signal_converters 6780 asp Connect the MR175 to the converter box and the RS232 side to the PC serial input c...
Страница 17: ...e command a for ASCII output and the output will now be in ASCII hex for each byte in the packet ASCII Hex output after the a command has been sent to the MR175 Move the controls on the MR175 and the...
Страница 18: ...opyl alcohol and wipe off the button area of the magnets until the metal shavings are removed and the magnet surface is clean again Magnets The magnets are covered with a silicon pad for protection of...