Micronics
U1000MKII User Manual
Issue 3.1 July 19
Page 11
Figure 11
M-Bus cable wiring
NOTE: ENSURE THE WHITE WIRES ARE CORRECTLY ASSOCIATED WITH THE BLACK &
BROWN WIRES. THE BLACK/WHITE TWISTED PAIR IS FITTED WITH A BLACK SLEEVE TO
DISTINGUISH BETWEEN THE BLACK/WHITE AND BROWN/WHITE PAIRS.
For reliable operation of a M-bus network the cable type and installation must comply with
requirements in the M-bus specification document:
Meter Communication Twisted Pair Baseband (M-Bus) Physical and Link Layer
For full immunity to electrical interference the screen of the power/pulse output cable and M-Bus
cable should be connected to Earth.