The SP6008P supports IEEE 802.3af/at standard for Power over 

Ethernet (PoE) with the maximum power delivery up to 120 Watts. 

That makes it suitable to various applications that demand for 

remote power feeding and meet high level requirement for power. 

SP6008P is totally equipped with 15.4Watts per port or max. 30 

Watts for one  port, which effectively helps allocate power for 

connected multiple devices and enhances network management.

Key Features

8 Port 10/100M Nway (Auto-negotiation) Switch

Supports IEEE 802.3az Energy-Efficient Ethernet

Supporting the power 15.4W per port or max. 30W for one port

Auto-learn of networking configuration

Auto-detect full/half-duplex modes for any port

Store-and-Forward switching methods

IEEE 802.3x flow control for full-duplex and back-pressure flow  

control for half-duplex

PoE total power budget 120W for all PoE  ports

Package Contents

Before you start installing SP6008P, please verify the following 

package contents:

SP6008P 10/100M PoE Switch 

Quick Installation Guide

Power Cord

Rackmount Kit

4

3

1

2

Tour of the System

Front Panel

LED indicators

Back Panel

Power Cord Connector

Hardware Installation

Desktop Installation

To install the switch on the desktop, follow these steps:

1. Set the switch on a flat surface strong enough to support the 

entire weight of the switch with all fittings.

2. Remove the adhesive backing papers from the rubber feet.

3. Turn the switch over and attach

 the supplied rubber feet to the

 recessed areas on the bottom 

at each corner of the switch.

4. Upturn the switch and set in the desired location, making sure 

there is enough ventilation space on all sides for proper air flow

5. Connect the switch to a power source with the provided power 

cord

Rack Installation

1. Secure the supplied rack-mounting brackets to each side of the 

switch with  supplied screws, as illustrated in the following figure 2

2. Use suitable screws (not provided) to secure the brackets to the 

rack, as  illustrated in the  figure 3

LED indicators

For definitions of LED indicators, please refer to the following table:

LED

Status

Power

Indication

On Green

Flash

On

Off

On

Off

Operation normally

The unit has no power connected

Flashing indicates activity

Port has established a valid connection

A PoE device is connected

No Power Device connected

Data

PoE

PoE Max. A
(Port1~4)

PoE Max. B
(Port5~8)

On Amber

On Amber

The total PoE power drawn from ports
1-4 is more then 60W

The total PoE power drawn from ports
5-8 is more then 60W

Installation  Preparation

To ensure a long-term and stable performance of the switch, pay 

attention to the following before installation.

Safety Requirement

Before cleaning the switch, disconnect the power supply. Do not 

clean the switch using a wet cloth, and never use any other liquid 

for cleaning. Take waterproof measures during storage, 

transportation and operation of the equipment.

Use only the power cord provided with the switch.

Make sure the voltage of the power supply meets the requirement 

of the input voltage of the switch.

Do not push any objects into the openings of the switch.

Ensure the vent holes are well ventilated and unblocked.

Do not open or remove the cover of the switch.

Location Requirement

Install the switch on a flat and stable surface that can support the 

entire weight of the switch with all fittings.

Locate the switch far from strong electromagnetic field generators 

(such as motors), vibration, dust, and direct exposure to sunlight.

To ensure adequate air flow around the switch. At least 10 cm (4 

inches) of space at the front and rear of the switch is needed for 

ventilation.

Make sure that the switch will be accessible and that the cables 

can be easily connected.

Position the switch away from water and moisture sources, be 

sure to provide an acceptable temperature and humidity operating 

environment. 