FIGURE 1. FRONT PANEL:
1.
Main power switch
2.
Hot air pencil input
3.
Temperature increase (UP)
4.
Temperature decrease (DOWN)
5.
Temperature display
6.
SET function key
7.
Hot air flow increase (UP)
8.
Air flow level display
9.
Hot air flow decrease (DOWN)
INSTALLATION
1.
Select the Nozzle that matches the size of the IC. Attach the nozzle when both the heating element and
the nozzle are cool and the unit is turned off and unplugged.
2.
Loosen the screw on the nozzle. Attach nozzle.
IMPORTANT:
Do not force the nozzle or pull on the edge of the nozzle with pliers. Also, do not tighten the set-
screw too tightly.
3.
In order to protect the pump during transportation, the pump in the machine is tightened by the 4
screws under the bottom enclosure. Please unscrew the 4 screws before the machine is first used.
(See Figure 2 above)
4.
Ensure that the base unit power switch is in the off position. Check carefully for any damage that may
have occured during transportation and ensure that the working voltage matches your power supply
before plugging in the station.
5.
Plug in the AC power cord and turn the main power switch to on. The temperature LED and airflow
LED displays will be on and show the value.
MICRON
4
FIGURE 2.
View showing base of solder station
Содержание T 1287